2-29
Chapter 2 Maintenance
8.
Measure the distance between the second copy side edge and the reference line, and name it
B. (Fig. 2)
(Fig. 2) j0mf42043
9.
Check that the value obtained by subtracting A from B is 0 ±1 mm.
Adjustment
Adjustment of Side 1
Procedure
1.
Enter
DC131
(715-015).
2.
If A in the Check Step 4 is
• 10.6mm or more, increase the NVM value.
• 9.4mm or less, decrease the NVM value.
(NVM 1 Step=0.04mm)
3.
Repeat the Check steps 1 to 5 and Adjustment steps 1 to 2 until the value is within the
specified range (A=10 ± 0.6 mm).
Adjustment of Side 2
Procedure
1.
After adjusting in single mode, make copies in the following modes to check the side
registration when duplex mode is selected.
• Paper Tray: 11 x 17"
• Reduction/Enlargement: 100%
• No. of Copies: 1
• Single/Duplex: 1 to 2-sided
2.
Check the Side Registration on the copies made in duplex mode in the same way as
described previously in "Check" items.
3.
If the adjustment is required, adjust in
DC131
[715-128] in the same way as in the single
mode.
Summary of Contents for DP-C321