3-273
Chapter 3 Troubleshooting
73. 755-091
[NVM Name]: No. of ShutDowns (BW)
[PSW Display]: #K_Shutdown Count - Black
[Initial Value]: 0
[Setup Range]: 0~65535 (FFFFh)
[Description]:
74. 755-092
[NVM Name]: No. of Setups (FC)
[PSW Display]: #K_Setup Count - Full Color
[Initial Value]: 0
[Setup Range]: 0~65535 (FFFFh)
[Description]: Accumulates the No. of Setups immediately after FC Job.
75. 755-093
[NVM Name]: No. of Setups (BW)
[PSW Display]: #K_Setup Count - Black
[Initial Value]: 0
[Setup Range]: 0~65535 (FFFFh)
[Description]: Accumulates the No. of Setups immediately after BW Job.
76. 755-094
[NVM Name]: First Install Date (Year)
[PSW Display]: #K_First Install - Year
[Initial Value]: 0
[Setup Range]: 0~99 (63h)
[Description]: Writes the date info when the first job was performed.
77. 755-095
[NVM Name]: First Install Date (Month)
[PSW Display]: #K_First Install - Month
[Initial Value]: 0
[Setup Range]: 0~12 (Ch)
[Description]: Writes the date info when the first job was performed.
78. 755-096
[NVM Name]: First Install Date (Year)
[PSW Display]: #K_First Install - Day
[Initial Value]: 0
[Setup Range]: 0~31 (1Fh)
[Description]: Writes the date info when the first job was performed.
79. 755-097
[NVM Name]: First install M/C SERIAL No._1
[PSW Display]: #K_First install, Part#1
[Initial Value]: 0
[Setup Range]: 0~65535 (FFFFh)
[Description]: Records the M/C Serial No. when the CRU was first installed.
80. 755-098
[NVM Name]: First install M/C SERIAL No._2
[PSW Display]: #K_First install, Part#2
[Initial Value]: 0
[Setup Range]: 0~65535 (FFFFh)
[Description]: Records the M/C Serial No. when the CRU was first installed.
81. 755-099
[NVM Name]: Last install M/C SERIAL No._1
[PSW Display]: #K_Last install, Part#1
[Initial Value]: 0
[Setup Range]: 0~65535 (FFFFh)
[Description]:
Records the M/C (2nd time onwards) Serial No. when the CRU was last installed.
82. 755-100
[NVM Name]: Last install M/C SERIAL No._2
[PSW Display]: #K_Last install, Part#2
[Initial Value]: 0
[Setup Range]: 0~65535 (FFFFh)
[Description]:
Records the M/C (2nd time onwards) Serial No. when the CRU was last installed.
83. 755-101
[NVM Name]: No. of M/C Serial No. Writes
[PSW Display]: #K_Machine Serial No. - Write count
[Initial Value]: 0
[Setup Range]: 0~65535 (FFFFh)
[Description]: Accumulates the No. of M/C into which CRU is installed.
84. 755-103
[NVM Name]: CRU TYPE
[PSW Display]: #K_CRU TYPE
[Initial Value]: CRU Type
[Setup Range]: 0~255 (FFh)
[Description]: CRU Type is recorded.
Summary of Contents for DP-C321
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......