ELE-10
2-13. Pedestal Adj. (P mode)
BOARD
PREPROCESS Board
TP
VIDEO OUT (G) (75 ohm terminated)
ADJ.
EVR
F No.
CLOSE
MODE
CAM
M. EQ.
Waveform Monitor
SPEC.
PEDESTAL = 0 %
±
1 %
1. Confirm that the lens is close.
2. Click
the
“12. Pedestal Adjustment P mode”
of the
camera adjustment software.
3. Operate
the
“ABB”
switch on the front of the Camera
and click
“OK”
.
4. Adjust the Slider on the PC so that the Pedestal level
becomes
0 %
±
1 %
as shown in 2-12.
5. Click
“>>”
.
6. After compleate the adjustment, click
“NORMAL 60I
(for NTSC)
”
or
“NORMAL 50I
(for PAL)
”
.
2-14. Pedestal Tracking VR Adj.
BOARD
PREPROCESS Board
TP
VIDEO OUT (75 ohm terminated)
ADJ.
VR701 (R PED TRACK), VR702 (B PED TRACK)
F No.
CLOSE
MODE
CAM
M. EQ.
Vector Scope
SPEC.
CENTER
1. Confirm that the lens is close.
2. Click
the
“13. Pedestal Tracking VR Adjustment”
of
the camera adjustment software.
3. Operate
the
“ABB”
switch on the front of the Camera
and click
“OK”
.
4. Adjust the slider so that the Black level becomes
0%
.
5. Set a gain of a vector scope to 10X.
6. Operate
the
“ABB”
switch on the front of the Camera
again.
7. Adjust
VR701 (R PED TRACK)
and
VR702 (B PED TRACK)
so that the black dot is on the center of the Vector
Scope.
8. Click
“>>”
.
9. Operate
the
“ABB”
switch on the front of the Camera
and confirm that the black dot is on the center of the
Vector Scope. If the black dot is not on the center,
adjust
VR701 (R PED TRACK)
and
VR702 (B PED TRACK)
again.
10. Click
“OK”
of confirmation
dialog box.
11. If the black dot is not on the center, adjust
VR701 (R
PED TRACK)
and
VR702 (B PED TRACK)
again.
12. Click
“NO”
of VR Adjustment
dialog box.
13. Operate the
“ABB”
switch on the front of the Camera
again.
14. If the black dot is not on the center, return to item 7 and
adjust
VR701 (R PED TRACK)
and
VR702 (B PED TRACK)
again.
15. Click
“YES”
of VR Adjustment
dialog box.
2-15. Standard Sensitivity Adj.
BOARD
PREPROCESS Board
TP
TP103 (R), TP303 (G), TP503 (B)
ADJ.
EVR
F No.
F11 + 1/2 (2,000lux)
CHART
Gray Scale
MODE
CAM
M. EQ.
Oscilloscope
SPEC.
A = 1,000mVp-p
±
10mV
1. Click
the
“14. Standard Sensitivity Adjustment”
of
the camera adjustment software.
2. Connect a scope to
TP103
(R-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
3. Click
“>>”
.
4. Connect a scope to
TP303
(G-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
5. Click
“>>”
.
6. Connect a scope to
TP503
(B-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
7. Click
“>>”
.
VR702
VR701
A
OB
PORTION
CENTER
OF NIOSE
Summary of Contents for AJSDX900P - 24P DVCPRO 50
Page 3: ... 3 ...
Page 4: ... 4 AJ SDX900E ...
Page 5: ... 5 ...
Page 7: ... 7 AJ SDX900P ...
Page 8: ... 8 AJ SDX900E ...
Page 9: ...FCD0307NTNK96E440E441 ...
Page 279: ...CBA 1 MOTHER P C BOARD VEP89140A FOIL SIDE FOIL SIDE REF LOC P6 C6 P11 A6 P13 A6 ...
Page 310: ...CBA 32 MENU SW P C BOARD VEP80C58A FOIL SIDE COMPONENT SIDE ...
Page 312: ...PRE REC P C BOARD VEP83608A AJ YA903G FOIL SIDE COMPONENT SIDE CBA 34 ...