MECH-53
Figure 2-24-3
Note:
If the cleaner Base Plate is removed, execute the
Cleaner roller Position adjustment.
2-24-2. Cleaner Roller Position
Adjustment
<Tools required>
Eccentric Driver (VFK0357)
1. Observe the clearance (A) between Cleaner
Roller and cylinder Unit as shown in Figure
2-24-4. And make sure that it is within 1.0 to
1.2mm.
2. If not, loosen the 2 screws (B) as shown in figure
2-24-2 and adjust the position of Cleaner Base
Plate by moving arrow direction (A
←→
A) using
the Eccentric driver so that the clearance (A) is
within the specification. And tighten the 2 screws
(B).
Figure 2-24-4
2-25. Distinction SW Unit
Replacement
(Studio VTR only)
(Removal)
1. Disconnect
the
connector (A)
on the
P.C.Board
(A)
. (Please refer item “7
2. . Table of Connector” about reference number of
connector and name of P.C.Board.)
Click this mark , then go to item “7. Table of
Connector”.
2. Remove the MIC Drive Rev Spring at Distinction
Switch Unit side as shown in Figure 2-25.
3. Unscrew the 3 screws (A) and remove the MIC
Rail Unit as shown in Figure 2-25.
(Installation)
1. Install the new Distinction Switch Unit following
the removal steps in reverse order.
2. Confirm that the M and L cassettes touch to
Distinction Switch Unit correctly.
Figure 2-25
DISTINCTION
SW UNIT
(A)
Summary of Contents for AJSDX900P - 24P DVCPRO 50
Page 3: ... 3 ...
Page 4: ... 4 AJ SDX900E ...
Page 5: ... 5 ...
Page 7: ... 7 AJ SDX900P ...
Page 8: ... 8 AJ SDX900E ...
Page 9: ...FCD0307NTNK96E440E441 ...
Page 279: ...CBA 1 MOTHER P C BOARD VEP89140A FOIL SIDE FOIL SIDE REF LOC P6 C6 P11 A6 P13 A6 ...
Page 310: ...CBA 32 MENU SW P C BOARD VEP80C58A FOIL SIDE COMPONENT SIDE ...
Page 312: ...PRE REC P C BOARD VEP83608A AJ YA903G FOIL SIDE COMPONENT SIDE CBA 34 ...