ELE-8
2-8. Pulse Cancel Adj.
BOARD
PRE AMP Board
TP
TP103 (R), TP303 (G), TP503 (B)
(PRE PROCESS Board)
ADJ.
EVR
F No.
-
MODE
CAM ON
M. EQ.
Oscilloscope
SPEC.
Level of center of noise = Level of BLK period
1. Click
the
“7. Pulse Cancel Adjustment”
of the camera
adjustment software.
2. Connect a scope to
TP103
(R-ch) and adjust the Slider
on the PC (EVR)
so that the center of the noise of
signal period and BLK period are the same.
3. Confirm that the level of horizontal blanking period is
not change during operating “GAIN” switch L, M, H.
If the level is changed, return to step 2 and adjust
again.
4. Click
“>>”
.
5. Connect a scope to
TP303
(G-ch) and adjust the Slider
on the PC (EVR)
so that the center of the noise of
signal period and BLK period are the same.
6. Confirm that the level of horizontal blanking period is
not change during operating “GAIN” switch L, M, H.
If the level is changed, return to step 5 and adjust
again.
7. Click
“>>”
.
8. Connect a scope to
TP503
(B-ch) and adjust the Slider
on the PC (EVR)
so that the center of the noise of
signal period and BLK period are the same.
9. Confirm that the level of horizontal blanking period is
not change during operating “GAIN” switch L, M, H.
If the level is changed, return to step 8 and adjust
again.
10. Connect a Vector Scope
then set the gain to Max.
11. Confirm the black dot is on the origin of the Vector
Scope during operating “GAIN” switch L, M, H.
If the black dot is moved, return to step 2 and adjust
again.
12. Click
“>>”
.
2-9. Test Signal Level Adj.
BOARD
PRE PROCESS Board
TP
TP103 (R), TP303 (G), TP503 (B)
(PRE PROCESS Board)
ADJ.
EVR
SIGNAL
Internal TEST Ramp Signal
MODE
-
M. EQ.
Oscilloscope
SPEC.
A = 1,000mVp-p
±
10mV
1. Click
the
“8.
Test Signal Level Adjustment”
of the
camera adjustment software.
2. Operate
the
“ABB”
switch on the front of the Camera
and click
“OK”
.
3. Connect a scope to
TP503
(B-ch) and adjust the Slider
on the PC so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
4. Connect a scope to
TP303
(G-ch) and adjust the Slider
on the PC so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
5. Connect a scope to
TP103
(R-ch) and adjust the Slider
on the PC so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
6. Click
“>>”
.
A
BLK
BLK
BLK
Center of the noise
Vector Scope (X5)
A
BLK
BLK
TP102: R
TP302: G
TP502: B
Summary of Contents for AJSDX900P - 24P DVCPRO 50
Page 3: ... 3 ...
Page 4: ... 4 AJ SDX900E ...
Page 5: ... 5 ...
Page 7: ... 7 AJ SDX900P ...
Page 8: ... 8 AJ SDX900E ...
Page 9: ...FCD0307NTNK96E440E441 ...
Page 279: ...CBA 1 MOTHER P C BOARD VEP89140A FOIL SIDE FOIL SIDE REF LOC P6 C6 P11 A6 P13 A6 ...
Page 310: ...CBA 32 MENU SW P C BOARD VEP80C58A FOIL SIDE COMPONENT SIDE ...
Page 312: ...PRE REC P C BOARD VEP83608A AJ YA903G FOIL SIDE COMPONENT SIDE CBA 34 ...