4
water care
The Water care page will help you set up your ideal filtration and heating settings.
Choose, set or modify one of the five suggested modes depending on your needs at any given time.
Away from Home
In this mode the
spa will always be in
economy; the set point
will be reduced
by 20°F.
Standard
The spa will never be
in economy mode
and will be filtering
according to the pack's
low level configuration.
Energy Savings
The spa will be in
economy mode during
the peak hours of
the day and resume
normal mode on
the weekend.
Super Energy
The spa will always
be in economy mode
during peak hours,
every day of the week.
Weekender
The spa will be in
economy mode from
Monday to Friday, and
will run normally on
the weekend.
modifying water care schedules
Water Care
To modify a Water Care category, touch the pencil
icon at the right end of the desired category to
open the selected menu.
In Economy mode, the set point will be reduced
by 20°F, which means that the heating system
will not be engaged unless the temperature falls to
20°F below the spa's set temperature.
The filtration schedule shown on the screen will
be applied to the main filtration pump, most likely
pump 1. If your spa uses a circulation pump
configured to run 24 hours, the screen will show
you the purge setting instead of filtration.
The purges are pre-programmed for a fixed
number of minutes, therefore the duration will be
set to N/A on the screen, and only the start time
can be modified.
Economy
Touch the Economy tab to change the economy
schedule. You can add economy schedules by
touching the orange line labelled "Add Economy" .
To delete a schedule, touch the garbage can icon
at the right end of the desired line.
You can modify the programmed schedules by
selecting one and adjusting the schedule.
You have several possibilities for the schedule
(Mon-Fri, weekend, every day, or single days).
The schedules will be repeated every week.
The time and duration are set in 30 minute
increments.
Purges
Touch the Purge Time tab to change the purge
settings. You can add purges by touching the
orange line labelled "Add Purge Time".
To delete a schedule, touch the garbage can icon
at the right end of the desired line.
Filter Cycles
Touch the Filter cycle tab to change the filter
cycle schedules. You can add filtration schedules
by touching the orange line labelled "Add Filter
cycle".
To delete a schedule, touch the garbage can icon
at the right end of the desired line.
Once you have set the schedule, press "Confirm".
If you don't want to keep any changes, press
"Cancel" or use the calendar icon to go back.
You can modify the programmed purges by
selecting one and adjusting the schedule.
You have several possibilities for the schedule
(Mon-Fri, weekend, every day, or single days).
The schedules will be repeated every week.
The time and duration are set in 30 minute
increments. Once you have set the purge,
press "Confirm". If you don't want to keep
changes, press "Cancel" or the calendar icon.
heat pump modes
Heat Pump
From the Settings page, you can access the
Heat Pump menu, which gives you access to
the following Heat Pump Modes:
∙ Eco Heat
∙ Smart Heat
∙ Eco Auto
∙ Smart Auto
∙ Cool
∙ Electric
Slide to make a selection and press on it to
confirm. When you select a Heat Pump Mode,
you will be asked to confirm your choice.
Note: If a Gecko Brand Heat Pump (in.temp) is
connected to your spa setup, the following Menu
will appear when selecting Heat Pump in the
Settings Menu instead of the Regulation Mode
Menu.
Est. Energy Saved
Only available with a Gecko Brand Heat Pump
(in.temp)
In this section, you can view your estimated
kWh economy graph. These calculations are
made while using in.temp to heat your spa. The
economy estimate can be viewed in days or
months format by pressing the button below
the graph.
Regulation Mode
The Regulation Mode page will help you set up
your ideal Heat Pump regulation settings. Choose
between Eco Heat, Smart Heat, Eco Auto, Smart
Auto, Cool and Electric, depending on your needs.
Touch the Regulation Mode name to choose your
setting. A green checkmark will appear on the
selected icon to confirm your choice.
When you select another Regulation Mode
setting, a confirmation window appears to prevent
inadvertent selection that could result in a setup
modification for your spa.
Eco Heat
In this mode, the
heat pump is used as
the unique source of
heating. The heating
element is kept off and
the heat pump is not
used to cool the water
should its temperature
rise above the current
set point.
Smart Heat
This mode uses the
heat pump as the
main heating source.
The heating element is
turned on only if there
is a large temperature
difference between
the water and the set
point. The heat pump
is not used to cool the
water in this mode.
Eco Auto
This mode borrows
functionality from both
Eco Heat and Cool
modes and has the
ability to select the
proper Heat or Cool
mode automatically
according to the
water temperature.
The heating element
is never activated
in this mode.
Smart Auto
This mode borrows
functionality from both
Smart Heat and Cool
modes and has the
ability to select the
proper Heat or Cool
mode automatically
according to the
water temperature.
The heating element is
activated only if there
is a large temperature
difference between
the water temperature
and the set point.
Cool
This mode uses the
heat pump in cooling
mode only. The heat
pump is not used as
a heating source and
the heating element is
never activated.
Electric
This mode keeps the
heat pump off and
uses only the heating
element to regulate
water temperature.
Disclaimer
The data provided by this tool is estimated by
sampling numerous operating parameters in real
time in order to generate an estimate that is as
close as possible to reality. The data is presented
to the users with the best intention but
Gecko Alliance Inc makes no warranty about
its accuracy or completeness. To increase the
accuracy of those estimates, ensure the heat
pump is well maintained and operates in the
recommended conditions in regards to water
flow, air exchange through the discharge panel,
adequate compressor pressure and cleanliness of
pipes and heat exchanger.