HC1
Pin 1 (Line 2)
Pin 2 (Output (1) high speed, 15A)
Pin 3 (Output (1) high speed, 20A)
Pin 4 (Ground)
Pin 5 (Neutral)
Pin 6 (Output (1) low speed, 15A)
Measuring tension on in.xe:
Example: your pump 1 high speed (240V) is not working.
Referring to the front connector identifiers, you may see the pump 1 output is on the P1 connector.
You may then refer to the “Connector pin out" on the front of the in.xe, you will notice the output for your pump 1 is on pins 2 and
3 (pump 1 high speed 20A and 15A) and the return should be on pin 1 (line 2) for a 240V pump and on pin 5 (neutral) for a
120V pump.
Measure the tension between P1 connector pins 2-3 (output pump 1 high speed 20A and 15A)
and pin 1 or 5 (return line 2 or neutral), you should measure:
120 V for a 120 V pump or accessory
240 V for a 240 V pump or accessory
LC (1)
Pin 1 (Line 2)
Pin 2 (Output (3), 5A)
Pin 3 (Output (3-4), 10A)
Pin 4 (Ground)
Pin 5 (Neutral)
Pin 6 (Output (4), 5A)
LC (2)
Pin 1 (Line 2)
Pin 2 (Output (4), 5A)
Pin 3 (Output (4), 10A)
Pin 4 (Ground)
Pin 5 (Neutral)
Pin 6 (NC)
HC2
Pin 1 (Line 2)
Pin 2 (Output (2) high speed, 15A)
Pin 3 (NC)
Pin 4 (Ground)
Pin 5 (Neutral)
Pin 6 (Output (3) low speed, 15A)
P1
P2
P2
P5
P1
P3
P5
P3
3
3
2
5
5 2
6
6
4
4
3
1
6
2
5
1
1
4
THE CIRCULATION PUMP IS NOT WORKING
If the circulation pump is
not working :
∙ Ensure the selected
low-level configuration is
compatible with your spas
material.
∙ Start the circulation pump,
by setting the set point
temperature 2°F above the
actual water temperature.
98
If the measured tension is
not compliant:
∙ Replace the accessories
fuse.
∙ If replacing the fuse
does not fix the problem,
replace the control system.
Measure the tension on the
corresponding connector:
∙ Referring to your control
systems connexion
diagram, measure the
tension between the
output of your circulation
pump and its return.
You should measure:
120V for a 120V
circulation pump
240V for a 240 V
circulation pump
THE OZONATOR IS NOT WORKING
Note:
The ozonator stops automatically when an accessory is started manually (i.e. pumps, blower, light).
If the ozonator is not
working:
98
If the measured tension is
not compliant:
If the ozonator is not working
and the filtration indicator
is ON:
∙ Referring to the connexion
diagram of your control
system, measure the
tension between the
ozonator output and its
return.
You should measure:
120V for a 120V
ozonator
240V for a 240V
ozonator
∙ Replace the accessories
fuse.
∙ If replacing the fuse
does not fix the problem,
replace the control system.
∙ Verify the status of the
filtration cycle indicator on
the keypad display.
∙ If the «Filtration» indicator
flashes, it signals that the
system has interrupted
the filtration cycle. In this
case, restart the breaker
then restart the power to
reinitialise the cycle.
∙ If the «Filtration» indicator
is not flashing, start the
filtration cycle (Refer to the
Quick Reference Card for
your keypad).
∙ Replace the ozonator.
If the measured tension is
compliant:
If the measured tension
is compliant:
∙ Replace the circulation
pump.