Y
Y
65
64
Note: This table shows typical connections. OEMs may have a different connection scheme.
* Ozonator and circulation pump can be combined on the same output via the optional splitter PP1.
Circulation pump* (A1)
Voltage
230 V
Green / ground
P51
Black / line
K4-P
White / common
P60
Light (12 V AC, 1A Max.)
Always on
P34
Relay
P35
Direct output 1 (A0 / Floating
connector) (in.ye-5-CE only)
Voltage
230 V
Green / ground
P47
Black / line
P32
White / common
P56
Pump 1 (A2)
(in.ye-5-CE)
Voltage
230 V
Green / ground
P50
Black / low speed
K6-P
Red / high speed
K3-P
White / common
P59
Pump 3 (A4)
(in.ye-5-CE only)
Voltage
230 V
Green / ground
P48
Black / line
K6-P
White / common
P57
Pump 1 (A3)
Voltage
230 V
Green / ground
P49
Black / low speed
K2-P
Red / high speed
K1-P
White / common
P58
Pump 2 (A2)
(in.ye-3-CE)
Voltage
230 V
Green / ground
P50
Black / low speed
K2-P
White / common
P59
Connecting High Voltage Accessories: European Model in.ye
For the connection to the 0.250 inch terminals, the high voltage accessories must be provided with female quick connect
terminals, straight and non-insulated for all types of connections, including the ground. Only 230 V accessories may be connected
to the corresponding terminals of the printed circuit of the in.ye. Refer to the following tables for correct connections. Note that all
female terminals must be correctly and completely seated on the printed circuit terminals for proper current ratings.
Direct output 1 (A4)
Voltage
230 V
Green / ground
P48
Black / line
P32
White / common
P57
Direct output 2 (C1)
Voltage
230 V
Green / ground
P92
Black / line
P132
White / common
P86
Auxiliary (B1)
(in.yt-12-ce only)
Voltage
230 V
Green / ground
P118
Black / line
K26-P
White / common
P124
Pump 1 (A3)
Voltage
230 V
Green / ground
P49
Black / low speed
K2-P
Red / high speed
K1-P
White / common
P58
Pump 5 (B3)
(in.yt-12-ce only)
Voltage
230 V
Green / ground
P115
Black / line
K24-P
White / common
P121
Pump 2 (A2)
Voltage
230 V
Green / ground
P50
Black / low speed
K6-P
Red / high speed
K3-P
White / common
P59
Blower (B4)
(in.yt-12-ce only)
Voltage
230 V
Green / ground
P114
Black / line
K25-P
White / common
P120
Pump 3 (C3)
Voltage
230 V
Green / ground
P94
Black / low speed
K22-P
Red / high speed
K21-P
White / common
P88
Circulation pump (C2)
(in.yt-12-CE)
Voltage
230 V
Green / ground
P93
Black / line
K23-P
White / common
P87
Circulation pump (C2)
(in.yt-7-CE)
Voltage
230 V
Green / ground
P93
Black / line
K22-P
White / common
P87
Pump 4 (B2)
(in.yt-ce only)
Voltage
230 V
Green / ground
P117
Black / low speed
K26-P
Red / high speed
K27-P
White / common
P123
Ozonator (A1)
Voltage
230 V
Green / ground
P51
Black / line
K4-P
White / common
P60
Light (12 V AC, 1A Max.)
Always on
P34
Relay
P35
Connecting High Voltage Accessories: European Model in.yt
For the connection to the 0.250 inch terminals, the high voltage accessories must be provided with female quick connect
terminals, straight and non-insulated for all types of connections, including the ground. Only 230 V accessories may be connected
to the corresponding terminals of the printed circuit of the in.yt. Refer to the following tables for correct connections. Note that all
female terminals must be correctly and completely seated on the printed circuit terminals for proper current ratings.
Note: This table shows typical connections. OEMs may have a different connection scheme.
14
14