Y
Y
59
58
4"
Floor Installation Procedure without Guide Plate
Part numbers:
9917-102148 (in.ye guide plate)
9917-100873 (in.yt guide plate)
The following materials
are recommended:
4 # 10 screws of
appropriate length with
round, truss or pan head.
4 washers .5" OD x .0625"
thickness (12 mm OD x
1.5 mm)
Guide plate
Now firmly attach the unit to
the wooden base by using the
remaining 2 screws backed
by 2 washers to attach the
front feet.
Note: The spa pack must be
installed at least 4" (100 mm)
above potential flood level. If
floor is on ground level, pack
should be raised at least 4"
(100 mm).
Slide the back side of the
unit's feet into the guide
plate. It should easily slide
into place.
Floor Installation Procedure with Optional Guide Plate
important
!
read
before
starting
:
Please note that countersunk screws should not be used as they can damage the power box support.
The heat.wav heating element must be installed in the return circuit of the main pump (pressure side).
The following materials
are recommended:
4 # 10 screws of
appropriate length with
round, truss or pan head.
4 washers .5 OD"
x
.0625"
thickness (12 mm
OD x 1.5 mm)
Now firmly attach the front
feet of the pack to the
wooden base using 2 more
screws backed by 2 washers.
Select the most appropriate
location on the floor for the
spa pack and firmly attach
the two rear feet to the
wooden base using 2 screws
backed by 2 washers.
Select the most appropriate
location on the floor for the
spa pack and firmly attach
the guide plate to the wooden
base using 2 screws backed
by 2 washers.
INSTALLATION
warning
!
Beware of the application of some products
commonly used against corrosion (such as
WD-40 family products) as they could damage
the pack, due to a negative chemical reaction
between some industrial oils and its plastic
enclosure. Any other materials which may
come in contact with the enclosure must be
carefully evaluated under end use conditions
for compatibility.
Part number:
Wall mount bracket kit 100 pieces - 9920-101474 (with 200
screws to attach to pack)
For detailed instructions and a drilling template, refer to the Techbook corresponding to your compatible keypad for the Y series
control system at www.geckodocs.com.
The following materials
are recommended:
4 # 10 screws of
appropriate length with
round, truss or pan head.
4 washers .5 OD"
x .0625"
thickness (12 mm OD x
1.5 mm)
Use two standard 2" x 4" or
2" x 6" wall studs, spaced
17-inch from centre to
centre to fix the spa pack.
Firmly attach lower mounting
holes on each side of the
pack with the 2 remaining
screws and 2 washers.
Lower mounting holes are
2" (51 mm) below the upper
holes.
Firmly attach, one at a time,
upper mounting holes on
each side of the spa pack
with 2 screws backed by 2
washers.
Install mounting brackets on
both sides of the rear of the
unit, using screws provided
with the bracket.
Torque screws to 13 in. lb
max (1.49 N.m).
Wall Installation Procedure with Optional Wall Mounting Brackets
Keypad Installation
14
14