Y
Y
73
72
Connect PJ1 between
P7and P13.
Connect PJ2 between
P10 and P74.
Connect PJ1 between
P7 and P10.
Connect PJ2 between
P13 and P74.
Connect PJ1 between
P7 and P10.
Connect PJ2 between
P13 and P74.
Connect PJ1 between
P7 and P10.
Connect PJ2 between
P11 and P13.
N
L3
L1
L2
PJ1
PJ2
G
L3
L1
L2
PJ1
PJ2
G
N
L1
L2
PJ1
PJ2
G
N
L1
PJ1
PJ2
G
1-phase
2-phase
3-phase Delta (no neutral)
3-phase
with single neutral
Electrical Wiring: European Model in.ye
Refer to wiring diagram in the enclosure box lid for more information.
Warning
in.ye.ce models must always be connected to a circuit protected by a Residual-Current Device (RCD) having a rated
operating residual-current not exceeding 30 mA.
Correct wiring of the electrical service box, RCD, and pack terminal block is essential!
Check your electrical code for local regulations. Only copper wire should be used, never aluminum.
Insert each wire into the appropriate socket of the main entry terminal block according to the colour code indicated on the sticker.
Use a flat-head screwdriver to tighten the screws on the terminal.
After ensuring wires are securely connected, push them back into the box and replace the cover. Do not over tighten cover screws
(torque to 8 in. lb max {0.9 N.m}).
Connect the bonding conductor to the bonding lug on the front of the spa pack (a grounded electrode conductor should be used
to connect the equipment grounding conductors).
PJ2
PJ1
N
L1
G
N
PJ2
PJ1
L1
L2
G
L3
PJ2
PJ1
L1
L2
G
N
PJ2
PJ1
L1
L2
L3
G
Connect PJ1 between
P7 and P13.
Connect PJ2 between
P10 and P74.
Connect PJ1 between
P7 and P10.
Connect PJ2 between
P13 and P74.
Connect PJ1 between
P7 and P10.
Connect PJ2 between
P13 and P74.
Connect PJ1 between
P7 and P10.
Connect PJ2 between
P11 and P13.
1-phase
2-phase
3-phase Delta (no neutral)
3-phase with single neutral
Warning
in.yt.ce models must always be connected to a circuit protected by a Residual-Current Device (RCD) having a rated
operating residual-current not exceeding 30 mA. Correct wiring of the electrical service box, RCD, and pack terminal block
is essential! Check your electrical code for local regulations. Only copper wire should be used, never aluminum.
Insert each wire into the appropriate socket of the main entry terminal block according to the colour code indicated on the sticker.
Use a flat-head screwdriver to tighten the screws on the terminal.
After ensuring wires are securely connected, push them back into the box and replace the cover. Do not over tighten cover screws
(torque to 8 in. lb max {0.9 N.m}).
Connect the bonding conductor to the bonding lug on the front of the spa pack (a grounded electrode conductor should be used
to connect the equipment grounding conductors).
Electrical Wiring: European Model in.yt
Refer to wiring diagram in the enclosure box lid for more information.
14