6.4.9
AUTO RMS Function – Steady State
The AUTO RMS mode, if enabled, causes the AC voltage output to be calculated as true RMS
voltage of the waveforms selected.
When disabled, RMS calculation of substituted waveforms does not occur so the output
voltage may change from the set value is the waveform is not a sine wave.
This mode can be set by sending the
[SOURce:]WAVEFORM:AUTORMS
command over one of the
Digital control interfaces.
Note:
In UPC Compatibility mode, this mode is always enabled.