Command Syntax
OUTPut[:STATe] <b>
Description
Enables or Disables power output. When enabled, all output relays are
closed. When disabled, all output relays are open. The time it takes for
the output to turn on is determined by the status of the OUTP:FAST
setting.
If the power source is in sleep mode (all power stages are off), it will
take about 2.2 seconds before the output relays are closed. This is
required to let all stages settle. If the power source is in standby mode,
it will only take 200 msec to close the output relay as only the second
(inverter) stage needs to settle.
Note: Sending the OUTP OFF command will only cause the second
stage to be turned off. The primary stages remain on and thus the AC
source will be in standby mode. If OUTP:FAST = 0, the primary stages
will turn off after 5 minutes of non-use and the AC source will enter
sleep mode.
Refer to section 6.2.2, “
” for more details.
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
OUTP ON
Query Format
OUTPut[:STATe]?
Returned Data Format
<b>
Query Example
OUTP?
1
Command Syntax
OUTPut[:STATe]:ALL <b>
Description
This command enables or disables the output and is similar to the
OUTPut[:STATe] command but always turns off all power stages,
regardless of the energy savings mode set with the OUTP:FAST
command. Thus, the OUTP:ALL OFF command will turn off all power
stages and put the AC source in sleep mode.
Note:
The OUTP:ALL ON command has the same effect as the OUTP ON
command.
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
OUTP:ALL OFF