AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 203 of 274
Query Format
SYSTem:HWREVision?
Description
Returns hardware revision of the power source
Returned Data Format
<nr1>
Query Example
SYST:HWREV?
0
Command Syntax
SYSTem:MODE
Description
Sets unit to either LOCAL or REMOTE mode of operation.
Parameters
<0 | LOCAL | 1 | REMOTE>
Parameter Format
<b>
Example
SYST:MODE REMOTE
Query Format
SYSTem:MODE?
Returned Data Format
<b>
Query Example
SYST:MODE?
1
Query Format
SYSTem:SERIALNUM?
Description
Returns the serial number of the power source. Same information can
be queried with the *IDN? command
Returned Data Format
<nr1>
Query Example
SYST:HWREV?
0
Query Format
SYSTem:FW:POWER:VERsion?
Description
Returns the revision number of the power source power stages.
Returned Data Format
<nr2>-<nr2>
Query Example
SYST:FW:POWER:VER?
80.7.10-76.0.0
Summary of Contents for 3120AFX