Command Syntax
[SOURce:]VOLTage[:AC]:LIMit:MAXimum
Description
Sets high user limit for AC voltage programming. User limits must fall
within actual hardware limits of the power source. Also, MAX limit
must be greater than MIN limit.
Parameters
0.000 – 300.000
Parameter Format
<nr2>
Example
VOLT:LIM:MAX 240.0
Query Format
[SOURce:]VOLTage[:AC]#:LIMit:MAXimum?
Returned Data Format
<nr2>
Query Example
VOLT:LIM:MAX?
240.0000
Query Format
[SOURce:]VOLTage[:AC]#:LIMit:RANGe?
Description
Returns available AC voltage range low and high limits.
Returned Data Format
<nr2>,<nr2>
Query Example
VOLT:AC1:LIM:RANG?
0.0000,300.0000
Query Format
[SOURce:]VOLTage[:AC]#:LIMit:ALLOwed:RANGe?
Description
Returns allowable AC voltage range low and high limits.
Returned Data Format
<nr2>,<nr2>
Query Example
VOLT:AC2:LIM:ALLO:RANG?
0.0000,300.0000