Query Format
PROGram[:SELected]:CHECK? [,<nr1>] [,<cr>]
Description
This command performs a check on the selected program steady state
and transient tables looking for the following conditions:
•
Hardware Limit violations
•
User Limit violations
•
Saturation limits.
If no violations are present, this command returns OK and the program
can be executed without generating any errors. If the selected program
cannot be run due to one or more issues with its content, one or more
errors detailing the issues will be returned.
For example, if the upper voltage user limit is set to 100V and the
program contains a setting of 300V, a “Cannot load program, Run
PROGRAM:CHECK?” error will be generated when attempting to
execute this program. When sending the PROGRAM:CHECK? Query,
the response will be “VOLT1 AC voltage setpoint cannot change due to
user limit”.
Parameters
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Returned Data Format
<cr>
Query Example
PROG:CHECK?
VOLT1 AC voltage setpoint cannot change due to user limit
Query Format
PROGram:EXECuted:CHECK? [,<nr1>] [,<cr>]
Description
This command serves the same purpose as the PROG:CHECK?
Command but applies to a program that is executing.
Parameters
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Returned Data Format
<cr>
Query Example
PROG:EXEC:CHECK?
VOLT1 AC voltage setpoint cannot change due to user limit
Command Syntax
PROGram[:SELected]:DELete
Description
This command deletes the selected program. Attempting to DELete an
EXECuting Program will result in an Error.
Parameters
Program number
Parameter Format
<nr1>
Example
PROG:DEL 9