AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 201 of 274
Command Syntax
SYSTem:ERRor:POE
Description
This command sets the Power on Error reporting mode. Returns status
of Power on Error setting as 1 (enabled) or 0 (disabled).
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
SYST:ERR:POE ON
Query Format
SYSTem:ERRor:POE?
Returned Data Format
<b>
Query Example
SYST:ERR:POE?
1
8.9.1
System Information Commands
Command Syntax
SYSTem:BEEP
Description
This command generates an audible beep at the front panel of the
power source.
Parameters
None
Parameter Format
n/a
Example
SYST:BEEP
Query Format
SYSTem:VERSion?
Description
Returns SCPI standard revision version.
Returned Data Format
<nr2>
Query Example
SYST:VERS?
1992.0
Query Format
SYSTem:LXI:VERSion?
Description
Returns LXI revision compliance version number.
Returned Data Format
<cr>
Query Example
SYST:LXI:VERSION?
LXI Core 2011
Query Format
SYSTem:LXI:FEATures?
Description
R eturns string listing supported LXI features.
Returned Data Format
<cr>
Query Example
SYST:LXI:FEAT?
None
Query Format
SYSTem:TIME?
Description
Returns real time clock date and time.
Note:
Since both date and time are returned, there is no
SYSTem:DATe?
Returned Data Format
<mm/dd/yy hh:mm:ss:mm
Query Example
SYSTem:TIME?
01/12/16 16:54:38
Summary of Contents for 3120AFX