AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 164 of 274
8.6.3
Transient Segments Commands
The following commands may be used to control stored transient program executions.
Command Syntax
PROGram:TRANsient
Description
This command controls transient execution
Parameters
RUN | STOP | PAUSe | STEP | RESTart
Parameter Format
<cr>
Example
PROG:TRAN RUN
Query Format
PROGram:TRANsient?
Description
Query format returns the transient execution state as either RUN,
STOP, PAUS, STEP or REST
Returned Data Format
<cr>
Query Example
PROG:TRAN?
RUN
Command Syntax
PROGram:TRANsient:AUTORMS <BOOLEAN>
Description
If enabled, the value of any waveform used in a transient segment is
normalized in order to match the RMS set point.
If disabled, the waveform is reproduced without any normalization.
This function is useful for waveform substitution at the steady state
level.
Note:
This function is related to the AUTORMS function in the steady
state segment.
Parameters
0 | 1 | ON | OFF
Parameter Format
<b>
Example
WAVEFORM:AUTORMS ON
Query Format
PROGram:TRANsient:AUTORMS?
Returned Data Format
<b>
Query Example
PROGram:TRANsient:AUTORMS?
1
Command Syntax
PROGram:TRANsient:AUTORMS
Description
This commands selected between legacy UPC controller mode
SEGMENT transient mode or STEP mode. Segment mode is backward
compatible with PPS UPC controllers and use a steady state table and a
transient table for each segment. A total of 99 segments can be
programmed. STEP mode uses the conventional SCPI LIST system of a
list of transient steps executed sequentially.
Parameters
SEGMENT | STEP
Parameter Format
<cr>
Example
PROG:TRANL:MODE STEP
Query Format
PROGram:TRANsient:MODE?
Returned Data Format
<cr>
Query Example
PROG:TRAN:MODE?
STEP
Summary of Contents for 3120AFX
Page 273: ......