AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 202 of 274
Query Format
SYSTem:TIME:SOURce?
Description
Queries source of date and time information.
Returned Data Format
<cr>
Query Example
SYST:TIME:SOUR?
NTP
Note:
NTP stands for “Network Time Protocol”. A protocol built on top
of TCP/IP that assures accurate local timekeeping with reference to
radio, atomic or other clocks located on the Internet. This protocol is
capable of synchronizing distributed clocks within milliseconds over
long time periods. It is defined in STD 12, RFC 1119 (RFC = Request for
comment. RFCs are used by the Internet Engineering Task Force (IETF)
and other standards bodies.
8.9.2
System Configuration Commands
Query Format
SYSTem:MAXKVA?
Description
Returns maximum available kVA output capability of the power source.
Example for 3150AFX model = 15.0000
Returned Data Format
<nr2>
Query Example
SYST:MAXKVA?
15.000
Query Format
SYSTem:MAXCURRent?
Description
Returns maximum available RMS or DC output current capability of the
power source. Example for 3150AFX model = 41.6667.
Returned Data Format
<nr2>
Query Example
SYST:MAXCURR?
41.6667
Query Format
SYSTem:MAXVOLTage?
Description
Returns maximum available RMS or DC voltage output capability of the
power source. Example for 3150AFX model = 300.
Returned Data Format
<nr1>
Query Example
SYST:MAXVOLT?
300
Command Syntax
SYSTem:COMPatible
Description
Sets Pacific Power Source UPC controller compatibility mode. This
mode allows use of the power source with legacy software.
Parameters
< 0 | DISABLE | 1 | UPC >
Parameter Format
Example
SYST:COMP UPC
Query Format
SYSTem:COMPatible?
Returned Data Format
<b>
Query Example
SYST:COMP?
1