AFX SERIES® OPERATION MANUAL
SECTION 5: UNPACKING AND INSTALLATION
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 41 of 274
5.13
Load Connections
WARNING
HAZARDOUS OUTPUT: The power source output may be set to hazardous voltage levels. It provides
basic isolation from the AC input mains. Therefore the output must always be considered
hazardous. Connections must be inaccessible to the operator in all situations when AC input mains
voltage is applied.
Always disconnect power supply from the mains before connecting or disconnecting to the
hazardous output terminals.
AVERTISSEMENT
SORTIE DANGEREUSE: La sortie de l´appareil peut être réglée à des niveaux de tension dangereux.
L´appareil fournit une isolation de base du réseau d'entrée AC. Par conséquent, la sortie doit
toujours être considérée comme dangereuse. Les connexions doivent être inaccessibles à
l'opérateur dans toutes les situations où la tension d´entrée secteur est appliquée.
Toujours débrancher l'alimentation secteur avant de connecter ou déconnecter les bornes de sortie
dangereuses.
The AC power source can be configured for either single phase output or three phase
output.
Note:
The External Voltage Sense connector always has three phase and three neutral
connections but in single phase mode of operation, only the A phase and one neutral
connection are required.
5.13.1
Output Wiring and Recommended Wire Sizing
Connections from the AC source output terminal to the load should be made using the
provided mating output connector. This connector is safety rated and does not require and
output cover. It MUST be used when connecting load wires.
Load current are a function of the load so care must be taken by the end user to select
appropriately size output wires in accordance with local electrical codes.
Maximum output voltage and current ratings of the available power source models are
shown in section 4, “Technical Specifications” and should be consulted when determining
correct wire size. Also consider the voltage insulation rating of the load wires and External
voltage sense wires used.
Summary of Contents for 3120AFX
Page 273: ......