Query Format
PROGram:TT? [<nr1>][,<nr1>] [,<cr>]
Description
This command returns the
T
ransient
T
able settings of the program
number specified. The format in which the data is returned can be
specified with the first parameter.
If no program number is passed as a parameter, the selected program
data is returned. See PROG:NAME for the selected program. The
steady state table data is not returned.
If no memory type is specified, the transient table stored in the
selected memory type is returned. See PROG:MEMORY for the
selected memory type.
Parameters
Option: STYLE [,<nr1]
0 = Human readable Style A (default if omitted)
1 = Human readable Style B
2 = Binary Data Format. Can be more useful to search for differences
between programs.
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Returned Data Format
<cr>
Query Example
PROG:TT? 1,2, USB
-> transient table program data
Formats for transient table shown below are:
Style A:
3,1,1,100.0,100.0,60.000,0.000,1.000|2.000|3.000,1,0.0|120.0|240.0
Style B:
3,1,1,100.0,100.0,60.000,0.000,0.000,0.000,0.000,1.000,1.000,2.000,3
.000,1,1,1,1,0.0,120.0,240.0
Binary:
000070420000000000000000000000000000803F0000004000004040
0000F0420000704301010100F4010000000070420000000000000000
000000000000803F00000040000040400000F0420000704301010100
F4010000