EXHAUST AFTER-TREATMENT SYSTEM
PART 7: STARTING & OPERATING THE VEHICLE
– 132 –
Y53-6032
(05/10)
WARNING! Never initiate an regeneration in a
closed building or enclosure. Always park
your vehicle outside and ensure no one is in
the immediate vicinity. Failure to do so could
ignite an explosion or harm bystanders which
could result in death or serious injury.
NOTES:Typical operation areas or materials that
can contain explosive vapors, flammable materi-
als or people in close proximity of the vehicle are
• Fuel depots
• Grain elevators
• Dry grass, leaves or trees
• Transfer refuse stations/dumps
• Parking lots
• Load/unload terminals
NOTE: While the list above may appear compre-
hensive, it is your responsibility to take the neces-
s a r y p r e c a u t i o n s a n d b e a w a r e o f y o u r
surroundings and ensure that no combustibles
(materials or vapors) or bystanders are close by
before initiating a regeneration.
4. Verify that the following conditions are met before pro-
ceeding. A Parked Regeneration will not initiate if any
of these conditions are not met.
• Parking brake is applied / set
• Engine is at low idle
• No throttle, brake or clutch applied
• PTO is disengaged
• Transmission is in neutral
5. Get out and walk all around vehicle to ensure that the
vehicle is at least 5 feet away from all combustible
materials and no one is in the immediate vicinity.
6. Climb back into the vehicle
7. Push the Regeneration (START) Switch located on
the dash for at least 4 -8 seconds and release the but-
ton to initiate a Parked Regeneration.
Y53-6032.book Page 132 Monday, May 24, 2010 3:37 PM
Summary of Contents for Peterbilt 587