2.7 Connecting Power Supply Cables
IMPORTANT:
Be sure that all external power supplies are turned OFF before
connecting them to the STATUS 18R mainframe. The supplies must have a minimum of
1.75 inches space between them for ventilation.
Power is interfaced via 16-pin circular plastic (CPC) connectors to the rear master panel
of the console. All consoles have at least two cables, Bipolar and Logic VCC.
If the console has Moving Faders, an additional rack supply and cable will be included
with the console.
The power supply cables are labeled at the connector ends.Plug the Bipolar cable into
the corresponding connectors on the console and power supply. Twist the locking ring
until it stops.
Follow the same procedure for the Logic VCC and Moving Fader power cables (if
supplied).
2.8 Connecting Eagle Automation
In order to use Fader and Mute automation, an IBM compatible computer must be
connected to the console. This PC is not included with the console and must be
supplied by the user.
2.8.1 Automation PC Specifications
The minimum specifications for the automation PC are:
• 486DX2-66 processor or higher operating on a Video Local Bus (VLB) or PCI Bus
motherboard (PCI Preferred)
• 15" or larger Color monitor capable of 800x600 resolution
• SVGA Video card with 1 Meg Ram. (VLB or PCI interface)
• 16 Meg System Ram
• 250 Meg Hard Disk Drive
• At least 1 COM Port using a 16550A High Performance UART. The presence of this
UART can be determined by running MSD at the C:> prompt of the PC in question.
• A Pointing Device such as a Mouse or Trackball. A second COM port is required if the
pointing device has a serial interface. If you have the Dynamics option and wish to use
the Graphical User Interface, you must use a COM port for Dynamics and have a bus-
type mouse or trackball.
• 20-foot (610 cm) maximum 9 pin serial cable (straight-pinned or extension-type). Do
not use a PC-to-PC serial cable.
2.8.2 Console Connection
The console communicates to the Automation PC using an RS-232 (COM) port.
Connect one end of the 9 pin serial cable to the DB-9 connector labelled
AUTOMATION
PC
on the rear of the Auxilliary panel. Connect the other end to the 9 pin DB-9
connector on the PC labelled COM 1 or COM 2.
For information on installing and configuring automation software, see
Section 6
,
Alignment and Maintenance
.
STATUS 18R
Operation and Maintenance Manual
Section 2 - Installation
August 1999
2 - 14
Console Power Supply Connectors
MF MOTOR
CONSOLE POWER
BIPOLAR / +48V
LOGIC VCC
Rear of Auxilliary Panel
AUTOMATION
PC
METER BRIDGE
TIME
CODE
OPTION
4
OPTION
3
OPTION
2
OPTION
1