5.5.9 Status Window
The Status window displays System and Mix Record status messages:
• READY (Red):
Record mode is active, time code is not running.
• READY (Yellow):
Safe mode is active, time code is not running.
• READY (Green):
Play mode is Active, time code is not running.
• PLAY (Green):
Play mode is active, time code is running.
• RECORD (Red):
Record mode is Active, time code is running.
• AUDITION (Yellow):
Safe mode is active, time code is running.
• WORKING (Red):
Eagle is processing Mix Data
• PRE ROLL (Green):
Eagle is syncing data to incoming timecode.
5.5.10 Record Controls Window
The Record Controls window is used to punch automation in and out of record and to
set the Safe mode.
• REC (Record):
When Rec is active, faders and switches I that are in Write or Update
are written to data. The Rec button allows fader and switch moves to be punched in at
a specific time.
• PLAY:
Pressing
PLAY
deactivates Record.
• SAFE:
When in Safe mode, the
REC
and
PLAY
buttons operate normally, but nothing
is written to data. This is used to prevent Rec from accidentally being pressed. Clicking
SAFE
toggles Safe mode on and off.
5.5.11 Tool Bar
The Tool Bar contains buttons that take you directly to frequently used windows and
functions. If a button is grayed out the function is not available.
Clicking the
Stopwatch
tool displays the Events window.
Clicking the
Fader knobs
tool displays the Mix Edit—Fader window.
Clicking the
Switch buttons
tool displays the Mix Edit—Switch window.
Clicking the
Data Scissors
tool displays the Mix Edit—Merge window.
Clicking the
Mix Gears
displays the Mix Processing window.
Clicking the
Track Sheet
button displays the Track Sheet window.
5.5.12 Info Bar
The Info Bar is used to display system statistics and help information.
STATUS 18R
Operation and Maintenance Manual
Section 5 - Eagle Automation
August 1999