Preset Section Controls
The Preset section controls work in conjunction with the
Preset/Key/Link
switch and
the
Preset
rotary encoder. To select a preset:
1.
Press the
Preset/Key/Link
select switch.
2.
Turn the
Preset
rotary encoder until the desired preset number is displayed
on the LCD.
All load and save operations are performed on the preset displayed.
• Gate Button:
When the
Gate
button LED is on, the gate preset will be will be loaded
or saved during a load or save operation.
• C/L Button:
When the
C/L
button LED is on, the compressor/limiter preset will be will
be loaded or saved during a load or save operation.
• Load Button:
Pressing
Load
while holding the
Preset/Key/Link
selection button
loads the selected gate and/or compressor/limiter preset into the currently selected
path’s dynamics module. The preset number and device(s) loaded depends on the
state of following controls:
- The preset number selected on the LCD.
- The On/Off state of the
Gate
button
- The On/Off state of the
C/L
button.
See
§B.5.6
for more information about dynamics presets.
• Save Button:
Pressing
Save
while holding the
Preset/Key/Link
selection button
saves the current gate and/or compressor/limiter settings into the currently selected
preset. The preset number and device(s) saved depends on the state of following
controls:
- The preset number selected on the LCD.
- The On/Off state of the
Gate
button
- The On/Off state of the
C/L
button.
See
§B.5.6
for more information about dynamics presets.
• Set All Button:
Pressing
Set All
and
Load
sets all gates and/or compressor limiters to
the currently selected preset The device(s) set depends on the state of following
controls:
- The On/Off state of the
Gate
button
- The On/Off state of the
C/L
button.
If
Set All
is pressed alone, the LCD shows “
PRESS LOAD TO SET ALL...
”
indicating that
Load
and
Set All
must be pressed together.
B - 8
August 1999
Appendix B Dynamics Option
STATUS 18R
Operation and Maintenance Manual
Set
All
Load
Save
Gate
C/L
Key
Preset
Link
Select
C/L
Preset Section