1.3 STATUS Specifications
Input Impedance
Microphone
> 2 k Ohms
Line Level Inputs
> 12 k Ohms
All Outputs
Impedance
< 50 Ohms
Nominal Level (Balanced Outputs)
+4 dBu
Nominal Level (Unbalanced Outputs)
+0.5 dBu
Maximum Level Before Clipping (Balanced Outputs)
+26 dBu
Maximum Level Before Clipping (Unbalanced Outputs)
+21.5 dBu
Maximum Gain
(Source to Track or Stereo Bus)
Microphone
74 dB
Line
48 dB
Tape
12 dB
Frequency Response
(At Nominal Level, Filters and EQ Out)
Line to Track Bus Out
10 Hz - 20 kHz, +0/-.25 dB
Mic to Track Bus Out
20 Hz - 20 kHz, +0/-.25 dB
Tape to Stereo Bus Out
10 Hz - 20 kHz, +0/-.25 dB
Noise
(20 Hz – 22 kHz, No Weighting, Input Termination 600
Ω
)
Mic (EIN 64dB Gain, 200 Ohms)
-127 dBu
Track Buses (1 Path Assigned, Unity Gain)
-86 dBu
Track Buses (16 Paths Assigned, Unity Gain)
-72 dBu
Stereo Buses (1 Path Assigned, Unity Gain)
-86 dBu
Stereo Buses (16 Paths Assigned, Unity Gain)
-72 dBu
Distortion
(THD+Noise, 20 Hz–20 kHz, at N4 dBu)
Line In to Track Out
0.05%
Tape In to Track Out
0.05%
Crosstalk
Between Track Buses (No Panner)
> 90 dB (1 kHz)
> 80 dB (20 Hz–20 kHz)
Between Stereo (L/R) Buses (Panner)
> 70 dB (1 kHz)
> 65 dB (20 Hz–20 kHz)
Current Draw
24/24 Mainframe
245 VA Typical
415 VA Max.
32/32 Mainframe
326 VA Typical
645 VA Max.
40/40 Mainframe
408 VA Typical
645 VA Max.
48/48 Mainframe
490 VA Typical
645 VA Max.
Console Heat Dissipation
24/24 Mainframe
466 BTU/Hr. Typical
790 BTU/Hr. Max.
32/32 Mainframe
621 BTU/Hr. Typical
1230 BTU/Hr. Max.
40/40 Mainframe
777 BTU/Hr. Typical
1230 BTU/Hr. Max.
48/48 Mainframe
932 BTU/Hr. Typical
1230 BTU/Hr. Max.
Power Supply Heat Dissipation
24/24 Mainframe
508 BTU/Hr. Typical
860 BTU/Hr. Max.
32/32 Mainframe
677 BTU/Hr. Typical
1215 BTU/Hr. Max.
40/40 Mainframe
847 BTU/Hr. Typical
1215 BTU/Hr. Max.
48/48 Mainframe
1016 BTU/Hr. Typical
1215 BTU/Hr. Max.
Power Supply Fuses
110 VAC, 5 Volt Supply
3 Amp Slow Blow
110 VAC, Bipolar 16 Volt Supply
3 Amp Slow Blow
110 VAC, +48 Volt Supply
1/2 Amp Slow Blow
220 VAC, 5 Volt Supply
1.5 Amp Slow Blow
220 VAC, Bipolar 16 Volt Supply
1.5 Amp Slow Blow
220 VAC, +48 Volt Supply
1/4 Amp Slow Blow
1 - 4
August 1999
Section 1 Introduction
STATUS 18R
Operation and Maintenance Manual