3.9.7 Connection compressed air supply
The compressed air maintenance unit is positioned behind the central lubrication unit.
Open the cover on which the central lubrication unit is located.
Connect the compressed air supply with at least 6.5 bars to the quick-action coupling of the
compressed air maintenance unit.
Adjust a pressure of 6.3 bars using the set screw of the maintenance unit.
Img.3-30: Compressed air maintenance unit
ATTENTION!
In order to ensure a failure-free operation of the machine it is necessary that the required
air pressure is continuously applied on the machine at constant quality. In case of
insufficient air supply, for instance interruptions occur during tool change.