10.5.2 Cleaning and replacing the filters on the internal CTS system
The internal CTS system is supplied with the coolant of the machine.
In order to clean or change the filter, the filter housing must be opened. To do this, loosen the
screws (1) on the filter housings.
Monthly - Clean the filter
Annually - Changing the filter
Img.10-10: external CTS unit
1
1
Suction filter (150
μ
m)
Outlet filter (40
μ
m)