Chapter 1
•
Configuring MGW x100
Configuring MGW x100 49
Note
To configure and manage MGW x100 via Telnet or MGW EMS, use the IP address
assigned to the NIC labeled Gig. Ethernet B on Controller A's I/O board (rear). Controller A
is installed in slot 7, which is labeled Control A (applicable only to MGWx100).
Enabling/Disabling Backup Channels
MGW x100 lets you add hot stand-by (backup) channels, which will take
over automatically if the primary channel fails.
If you do not want hot stand-by channels to take over, you can use the
command line interface to disable the relevant codes.
To disable codes:
1.
Use Telnet or HyperTerminal to access the command line interface as
explained on the previous pages.
2.
At the command prompt, type
excludeChFcodes 2010 2014
and press
Enter
; the relevant codes are disabled and hot stand-by channels will not
take over when sources become unstable.
3.
To preserve this setting, type
save excludeChFcodes 2010 2014
and
press
Enter
; the codes remain disabled after restarting MGW x100.
To restore disabled codes:
1.
At the command prompt, type
excludeChFcodes 999999
and press
Enter
; the relevant codes are restored.
2.
To preserve this setting, type
save excludeChFcodes 999999
and press
Enter
; the relevant codes remain active after restarting MGW x100.
StockCheck.com