Chapter 4
•
Troubleshooting
Troubleshooting 173
after the connection
was terminated.
the Current Users list by using
Force
Logout
.
The Problem
Possible Cause
Possible Solution
I am logging on to a unit, but
the user name appears to be
invalid.
The user name
and/or the password
are incorrect.
Refer to the notes that you made or
use one of the standard users to log
on. User names and passwords are
case sensitive. Make sure that
Caps
Lock
is switched off on your keyboard.
You may try to log
on as a user that
has been defined for
a different MGW
unit.
Users that you may have added using
MGW EMS are specific to an MGW
unit and not to your copy of MGW
EMS. To log on and view currently
defined users, use a default user
a
nd
refer to the Users/Permissions table
available from the Login menu in MGW
EMS.
The connection was
terminated while being
logged on as
Super User
.
'Try' to log on as
Super User
; MGW
x100 logs you on as
Guest
. In this
specific case, you can remove the
Super User entry from the Current
Users list by using
Force Logout
.
Operating Channels
This section lists basic errors that you may encounter. In most cases, an alarm
or error message will appear and define the error.
General
The Problem
Possible Cause
Possible Solution
The Hot Swap LED remains
blue.
You just inserted the
board or you opened
an Injector/Ejector
handle.
Wait until the Hot Swap LED is off and
the Status LED turns green.
If you opened one of the
Injector/Ejector handles by mistake,
remove and then re-install the board.
The Status LED is red.
Board or slot error.
Check whether the associated I/O
board has been installed opposite to
the service board. The slot numbers at
the front and the rear must match.
Remove this board and try installing in
another slot.
If the Status LED turns red again,
replace the Encoder Service board. If
the Status LED turns green, re-install
both the Encoder I/O and the Encoder
Service boards in a different slot.
Check the pins inside the slot and on
the board for mechanical damage. Call
for technical support.
In MGW EMS, the board is
labeled
Unknown
or the slot
appears empty. All LEDs are
The board is not
connected.
Make sure that the service board has
been properly inserted and that the
brackets are closed.