Maintenance Functions - 113
NOTE:
You may read the openings of more than one
lock. You will be allowed to select which lock openings
to print at the front desk console.
Test
The TEST function will test most functions of the lock,
including the batteries, the electronics and the handle
switches. It will also indicate the reason a card was
rejected in a lock. A good time to test each lock is
during the time change that occurs twice each year,
since you are at the door with the PP.
To test each lock, follow these steps:
1.
Connect the PP to the lock, turn it on and select
TEST with the MENU key.
2.
Press the green TX key. This will show you the room
number of this lock, the lock type and version, the
door number and will test the red and green lights.
3.
Press the TX key again. This will show the date and
time in the lock and test the batteries. You should see
"Batteries OK". If not, replace the batteries.
4.
Press the TX key again and operate the outside
handle, the deadbolt, and insert a card. For each of
these operations you should see a message that
indicates that the corresponding switch in the lock
was activated. If you do NOT see a message for any
of these operations, or if the message remains on the
screen after you have completed the operation, the
lock needs to be repaired.
5.
Press the TX key again. If your lock has a keyboard,
press the buttons. The character you press should be
displayed.
6.
Press the TX key again. You will see “MAN. DATE”
and the manufacturing date of the lock electronics.
7.
Disconnect the PP.
8.
Insert and remove the Diagnosis Card. You should
see a green light. Go to the next door.