UHF RFID System 

 
 

User’s Manual 

 
 

 
 
 
 

V750-BA50D04-SG(-MY) (Mono-static Reader/Writer) 

V740-HS01CA (Circular Antenna) 

V740-HS01LA (Linear Antenna) 

 

 

 

 
 

 

 

 

 

 

Manual No. SRFM – 015 – A

 

Reader/Writer 

Antenna

Summary of Contents for V740-HS01CA

Page 1: ...1 of 135 V750 series UHF RFID System User s Manual V750 BA50D04 SG MY Mono static Reader Writer V740 HS01CA Circular Antenna V740 HS01LA Linear Antenna Manual No SRFM 015 A Reader Writer Antenna ...

Page 2: ...D IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR SUITABLITY FOR USE OMRON SHALL NOT BE RESPONSIBLE FOR CONFORMITY WITH ANY STANDARDS CODES OR REGULATIONS THAT...

Page 3: ...ity to operate the equipment and could create a hazardous condition Copyright OMRON Corporation 2007 All rights reserved This document is protected by copyright and is intended solely for use in conjunction with the product Notify your OMRON representative before copying or reproducing this document in any manner for any other purpose Declarations ...

Page 4: ...jury or property damage Property damage refers to extended damage caused to house household goods or livestock pets Description of Symbols Prohibition Indicates an action or activity not permitted Observe strictly Indicates the need to ensure the safe use of the product Ensure to establish a solid grounding A label indicating that a device with a grounding terminal should always be grounded Electr...

Page 5: ...Failure to do so may results in electric shock fire or personal injury Connect and disconnect cables as described in the following procedures when installing moving on this product or attached devices To connect To disconnect 1 Attached all cables to devices 1 Remove power cords from outlet 2 Attached power cords to outlet 2 Remove all cables from devices Failure to do so may result In spark or de...

Page 6: ...ns where the device may be exposed to water oil or chemical agents This applies to the models other than waterproof types Outdoor Be sure to tighten the devices screws securely z Failure to do so may result in personal injury or device damage Cables with screw attachments must be secured before use z Failure to do so may damage the device To avoid interferences with other systems adhere to the fol...

Page 7: ...sure that terminal blocks and connectors are connected in the specified direction with the correct polarity Not doing so may result in malfunction If the power supply for the I O circuits is turned ON with the input and output connectors reversed the fuse of output transistor may be blown Do not apply voltages to the input terminals in excess of the rated input voltage Excess voltages may result i...

Page 8: ...unication with Tags If the product is required in the vicinity of these items check for any interferences prior to use To avoid interferences with other systems adhere to the following items and check them before using the product On the contrary the system itself may affect radio station transmissions or medical devices Be cautions when using the system in the environments where such effects migh...

Page 9: ...5 1 4 5 Status Indicators 27 1 4 6 I O Interface 29 1 4 7 RS 232C Interface 34 1 4 8 Ethernet Interface 36 2 Functions and Control 37 2 1 Reader Operating Mode 37 2 2 System Interface 38 2 2 1 Command I F Function 38 2 2 2 Reader Configuration 39 2 2 3 Web Browser Function 40 2 3 Functions 41 2 3 1 Command Execution 41 2 3 2 Digital Input Output 41 2 3 3 Self Operation 42 2 3 4 Firmware Update 43 ...

Page 10: ...ion Mode 101 4 2 1 Page List 101 4 2 2 Status 102 4 2 3 Reader Settings 105 4 2 4 Communication Settings 108 4 2 5 Operation Settings 111 4 2 6 Communication Test 114 4 2 7 Utility 116 4 2 7 1 Latest Error Logging 116 4 2 7 2 History of Error Logging 118 4 2 7 3 Noise Check 120 4 2 8 Firmware Update 122 4 3 Safe Mode 123 4 3 1 Status Page 123 4 3 2 Firmware Update Page 125 4 4 Update Mode 126 5 Co...

Page 11: ...nd transfers data to a remote computer over a network connection WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTICE This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...

Page 12: ...ange communication and for the system construction used in the production process or distribution control It is designed to have High read range Quick response and Simple operation Network Conveyor system Dock door system PLC Host Ethernet RS 232C V750 Reader V750 Reader Server ...

Page 13: ...ia objective such as data value or tag count 2 Rich maintenance functions and on site verification functions 1 Monitoring and setting via Web browser Via Web browser you can get an operation status or setting conditions and set the operation parameters easily 2 Communication monitoring function that reduces the installation time A tag communication testing function an on site environmental monitor...

Page 14: ...e tests conducted under typical operating conditions at your site are recommended to help you to optimize system performance Tag Variables There are several variables associated with tags that can affect reader performance Application surface Some materials interfere with tag performance including metal and moisture Tags applied to items made from or containing these materials may not perform as e...

Page 15: ... or reduced by using either one or both of the following strategies Affected antennas may be synchronized by a separate user application using a time multiplexing strategy Antenna power can be reduced by reconfiguring the RF Transmit Power setting for the reader ...

Page 16: ...W Operation temperature 10 to 50 C 14 to 122 F Humidity 25 to 85 RH non condensing Storage temperature 25 to 65 C 13 to 149 F Dimensions 246 x 215 x 43 5mm 9 7 x 8 5 x 1 7 inch Protection class IP50 Vibration resistance 10 to 150 Hz Amplitude 0 1mm Shock resistance 150m s2 15G Case material Aluminum Weight 1 4kg 3 1 lbs Mounting 4 point screw M4 1 2 2 Outline Drawing ...

Page 17: ...EEE802 3 compliance 10Base T IEEE802 3u compliance 100Base TX Supported protocol TCP IP Port 7090 Changeable RS 232C Supported standard RS 232C compliance Baud rate 9 6 19 2 38 4 57 6 kbps Data length 7 8 bits Parity Even Odd None Stop bit 1 2 bit Browser interface Ethernet Protocol HTTP Port 80 Fixed TCP IP Port 7091 Changeable Digital Input Output 4 Inputs 4 Outputs Status indicator 8 Operation ...

Page 18: ...P50 Operating temperature 10 to 50 C 14 to 122 F Operating temperature 10 to 50 C 14 to 122 F Storage temperature 25 to 65 C 13 to 149 F Storage temperature 25 to 65 C 13 to 149 F Relative humidity 25 to 85 RH non condensing Relative humidity 25 to 85 RH non condensing 1 3 2 Antenna Cables The only cables used with the V750 reader are listed below Short cable Options Long cable Options Model V740 ...

Page 19: ...aximum RF power 35dBm 3 28W e i r p 2W e r p Antenna Gain Cable Loss For example if the antenna has a maximum gain of 6 dBi and the cable has a minimum loss of 1 5 dB the maximum RF power that may be set is 35 6 0 1 5 30 5 dBm The reader RF Power is set through the Communication Settings Page as described on Page107 Recommended Power Settings Antenna Type Short Cable Long Cable Super Long Cable V7...

Page 20: ...rt the M4x16 screws with spring washers and flat washers and tighten until almost flush with the wall Two persons one for hold the reader and the other for tighten the screws are required for this installation for the safety 4 Tighten the screws securely 5 Place the external power supply where it is not obstructed and fix it so that not to move by vibration and tense DC cable Do not bundle the cab...

Page 21: ...e 4 of those with diagonal position according to the mounting location 2 Drill holes for the screws and install wall anchors if required 3 Insert the M4x20 screws with spring washers and flat washers and tighten until almost flush with the wall 4 Tighten the screws securely Note For best performance mount the antenna in the horizontal orientation as pictured above Mounting holes ...

Page 22: ...ects to the input output signal cable s via an attached I O port adapter MC 1 5 10 STF 3 81 4 Inputs connects with the sensor that works as a trigger signal for communication start 4 Outputs connects with the light or actuator that is driven by output signal MC 1 5 10 GF 3 81 produced by PHOENIX CONTACT DC Power input POWER DC12V Connects the Reader to an external 12VDC power supply with the attac...

Page 23: ...rnal power supply Power supply type Output voltage Current capacitance UL508 Class 2 circuit 12VDC 10 2 5A or more The recommendation power supply is S8VS 03012 or S82K 03012 OMRON Note Ensure correct polarity when connect the DC cable to the power supply DC cable polarity Red wire 12VDC Black wire 0V DC cable V750 A01 AC side DC power supply S8VS 03012 12VDC 0V DC side DC power supply S82K 03012 ...

Page 24: ...24 of 135 WARNING Be sure to use a UL508 Class 2 power supply Failure to do so may result in electric shock or fire ...

Page 25: ...antenna ports before applying power to the reader Any antenna port that has detected no antenna will be disabled when the reader is powered on Antenna Connection V750 BA50D04 SG MY Note With the two antenna configuration there is a possibility that a tag may be read by an inactive antenna if the tag is located with in approximately 20 cm of the inactive antenna with powered at 31 5 dBm 2 Verify th...

Page 26: ...ll back to the static IP address Default IP address 192 168 1 200 Subnet mask 255 255 255 0 Gateway 192 168 1 254 4 Plug the power adapter provided with the reader into the DC power input connector Then connect the AC power cord to a power outlet While the reader is powering up the Power indicator is lighting After the reader finishes its power on self test approximately 5 seconds RUN indicator wi...

Page 27: ... stopped by settings ex Power shut down in command communication ex Communication setting error ex Disconnection to the DHCP server ERR Reader error RUN indicator off Unrecoverable error RUN indicator on Recoverable error Red Flashing Long interval Waiting for network connection Communication result Normal end Green ON Command executed or communication with tag completed normally Turns off after 5...

Page 28: ...it lights for 50ms ANTENNA 4 Antenna port 4 Orange ON Communication process is running via antenna 4 When connecting with an antenna via antenna 4 is detected after power turns on it lights for 50ms 1 Input port 1 Green ON Signal of input port 1 is on 2 Input port 2 Green ON Signal of input port 2 is on 3 Input port 3 Green ON Signal of input port 3 is on IN 4 Input port 4 Green ON Signal of input...

Page 29: ...put common port How to wire a terminal block connector with signal cables s and how to connect it to the reader body 1 Wire a signal cable s to the terminal block connector Loosen the cable fixing screw s anticlockwise and insert the signal cable s all the way into the connector Tighten the cable fixing screw s clockwise 2 Mount the terminal block connector to the reader body 3 Fasten the terminal...

Page 30: ...f input 4 inputs 1 common input Input method Photo coupler Input voltage DC10 2 26 4V Input impedance 2 35kΩ TYP Input current 12V 4 5mA 24V 9 8mA TYP Wiring Wiring in the input terminal block IN1 6 IN2 7 IN3 8 IN4 9 IN_COM 10 Filter Fuse Secondary side internal circuit ...

Page 31: ...peripheral devices MC 1 5 10 STF 3 81 PHOENIX CONTACT DC Power supply 12V to 24V NPN transistor output Open collector type ex 3 line type sensor PLC output unit NPN output Switch Sensor Circuit PLC Circuit IN1 6 IN2 7 IN3 8 IN4 9 IN COM 10 ...

Page 32: ...pen collector output Sync type NPN Output maximum level 26 4V 13mA Leak current Less than 100μA VCE Sat Less than 3V When output level is 13mA Less than 2V When output level is 10mA Wiring Wiring in the output terminal block 二 次 側 内 部 回 路 OUT1 1 OUT2 2 OUT3 3 OUT4 4 OUT_COM 5 Filter Fuse Secondary side internal circuit ...

Page 33: ...33 of 135 Example of the wiring with peripheral devices MC 1 5 10 STF 3 81 PHOENIX CONTACT IN PLC Input unit Relay Circuit Circuit DC Power supply 12V to 24V COM OUT1 1 OUT2 2 OUT3 3 OUT4 4 OUT_COM 5 ...

Page 34: ... PC or PLC Programmable logic controller If you use the PC as a host prepare a cross cable to connect the PC to the port Connector D sub 9pin male inch screw 4 40 Pin assignment Pin No Name I O Function 1 2 RD IN Receive Data 3 SD OUT Send Data 4 5 SG Signal Ground 6 7 RS OUT Request to Send 8 CS IN Clear to Send 9 5 9 1 6 ...

Page 35: ... 1 RD 2 2 RD SD 3 3 SD ER 4 4 SG 5 5 SG DR 6 6 RS 7 7 RS CS 8 8 CS PC RI 9 9 V750 reader Connecting to the Omron s PLC programmable logic controller Serial setting is set for flow control none D sub 9 pin male M2 6 screw D sub 9pin female inch screw Signal name Pin number Pin number Signal name 1 1 SD 2 2 RD RD 3 3 SD RS 4 4 CS 5 5 SG 6 6 7 7 RS 8 8 CS PLC Programmable Logic Controller SG 9 9 V750...

Page 36: ...l cable 10 10Base T Connector RJ 45 8 pin LED Link green Act orange Link lights while linking normally Act lights when detects a carrier Pin assignment MID type Pin No Name I O Function 1 TXD OUT Transmit Data 2 TXD OUT Transmit Data 3 RXD IN Receive Data 4 Reserved 5 Reserved 6 RXD IN Receive Data 7 Reserved 8 Reserved Link Act 1 8 ...

Page 37: ... the reader communicates tags normally Safe Mode Under this mode the reader recovers or is maintained after error If you push the Mode Switch for 1 second or more and release the switch while the system is running or if the reader detects an error ex System error or a failure of firmware update and it can not start up normally due to this error the reader will start up under Safe Mode Under this m...

Page 38: ...and the port number over 1024 can be changed by using a setting command or Web page If the reader can not detect the DHCP server under dynamic IP address setting it will flash the error indicator and start up with static IP address Ethernet network settings Item Factory default DHCP Disable IP Address 192 168 1 200 Subnet Mask 255 255 255 0 Gateway 192 168 1 254 Communication Port 7090 2 RS 232C T...

Page 39: ... If you are using DHCP you must have a means of finding the reader typically by having a DHCP server update a DNS server How to change network settings is as the following 1 Exit any reader applications that are running on the network IMPORTANT Running another reader application while using the browser based interface may cause a reader error If this happens reboot the reader or restart the system...

Page 40: ... entry and programmable output conditions Communication Test Executes a communication commands Utility Provides some functions for easy installation and maintenance Latest Error Logging The function to display the latest error log History of Error Logging The function to display the counted error log Noise Check The function to monitor an on site environment Firmware Update Provides the method to ...

Page 41: ...oise check 2 3 2 Digital Input Output 1 Digital input Following two functions can be assigned to 4 digital inputs respectively To assign the function set via Set Operation window of command or Web User Input reads ON OFF state by receiving the command from the host Command entry executes registered command series at the rising edge of input signal 2 Digital output Programmable output Following thr...

Page 42: ...y given command The rising edge of input 1 signal Any given command The rising edge of input 2 signal Any given command The rising edge of input 3 signal Any given command The rising edge of input 4 signal Any given command WARNING DO NOT enter the reset command at executing timing of start up IN1 IN2 IN3 IN4 Power On Entered command at Start Up Start process End process If another command is runn...

Page 43: ...ation process is returned the reader sends judgment signal depending on the specified conditions to the corresponding Digital output port 1 4 This function provides two judgment and output time for each output port Available conditions Function Output timing Condition setting Option NORMAL The process is finished normally The read written tag count Operator Compared number Data comparison Operator...

Page 44: ...e tag once and repeats the transaction until termination has been instructed Multi Once Reads multiple tags once for a specified period Communication sequence Option Multi Repeat Reads multiple tags and repeats the transaction until termination has been instructed Antenna sequence Option Antenna port number Antenna sequence number 1 2 3 4 Sets maximum 9 antennas sequence GEN2 Session value S0 S1 S...

Page 45: ...romptly Single Repeat This is used for communicating with a single tag in the communication field Just after the communication transaction the result is returned promptly Following the return the reader carries out the transaction repeatedly with other tags Multi Access Mode This method is used for communicating with one or more tag s in the communication field It is suitable for the place where t...

Page 46: ...detects one tag for the specified period A sequence when the reader does not detect any tag for the specified period There is no tag Host Reader Tag Command Read tag Process Detecting and reading tag Tag A Response Tag No 1 Tag ID A Host Reader Tag Command Read tag Process Detecting and reading tag Tag A Response Tag No 1 Tag ID A Host Reader Tag Command Read tag Process Detecting and reading tag ...

Page 47: ...ponse Tag No 1 Tag ID A Host Reader Tag Command Read tag Process Detecting and reading tag Tag A Response Tag No 1 Tag ID A Period Timeout Host Reader Tag Command Read tag Process Detecting and reading tag Host Reader Tag Command Read tag Process Detecting and reading tag Period Timeout Just after the reader communicates the tag it returns a response reporting the read tag data to the host The rea...

Page 48: ...Read tag Process Reading tag Tag A Response Tag No 1 Tag ID A Process Reading tag Tag B Response Tag No 1 Tag ID B Process Reading tag Tag C Host Reader Tag Command Read tag Process Reading tag Tag A Response Tag No 1 Tag ID A Process Reading tag Tag B Response Tag No 1 Tag ID B Process Reading tag Tag C Host Reader Tag Command Read tag Process Reading tag Response Tag No 0 Tag ID None Process Rea...

Page 49: ...mmand Read tag Process Detecting and reading tag Tag C Response Tag No 3 Tag ID A B C Period Timeout Tag A Tag B Host Reader Tag Command Read tag Process Detecting and reading tag Tag C Response Tag No 3 Tag ID A B C Tag A Tag B Host Reader Tag Command Read tag Process Detecting and reading tag Response Tag No 0 Tag ID None Host Reader Tag Command Read tag Process Detecting and reading tag Respons...

Page 50: ...g Response Tag No 2 Tag ID D E Process Reading tag Tag D Tag E Tag F Host Reader Tag Command Read tag Process Reading tag Tag C Response Tag No 3 Tag ID A B C Tag A Tag B Process Reading tag Response Tag No 2 Tag ID D E Process Reading tag Tag D Tag E Tag F Period Timeout Period Timeout Host Reader Tag Command Read tag Process Reading tag Response Tag No 0 Tag ID None Process Reading tag Response ...

Page 51: ...Reading tag ANT 3 ANT 2 Host Reader Command Read tag Process Reading tag Response ANT 4 ANT 3 ANT 2 ANT 1 ANT 4 Process Reading tag ANT 3 ANT 2 Period Timeout Host Reader Command Read tag Process Reading tag Response Tag No n ANT 4 Process Reading tag Response Tag No n Process Reading tag ANT 3 ANT 2 ANT 1 ANT 4 Process Reading tag ANT 3 ANT 2 ANT 1 ANT 4 ANT 3 ANT 2 ANT 1 ANT 4 ANT 3 ANT 2 ANT 1 ...

Page 52: ...ergizing stopped It means that the tag is not re read unless the tag stays out of the communication field for the specified time S2 Factory default setting In this setting the reader communicates with new detected tags existing in the communication field during the command execution S0 When there is a tag the reader can not read because of flag conflict with other readers this setting enables the ...

Page 53: ...the number of PC EPC bit NSI To selectively read the specified tags that have certain supplier s IC 2 Smoothing function Smoothing function consists of following three types Using this function the reader can reduce the data transferred between the host and the reader 1 Prevention of response duplication The reader can prevent duplicated responses of same tag ID in a one response 2 Prevention of r...

Page 54: ...o be read before hand use this mode The value must be the greatest of the EPC word lengths of the tags to be read Ex1 When EPC word length of a communicating tag is unknown set EPC word length to 0 auto mode Tx SETC ewl 0 Rx SETC0000 Ex2 When EPC word length of a communicating tag is known beforehand set the word length For example set it as follows when all EPC length of a communicating tag are 9...

Page 55: ...y data that is read only is in bank 10 TID Area User data is in bank 11 User Area For the detailed information refer each tag s specification Bank block number Bit Contents 0 00 0F Kill Password 31 16 1 10 1F Kill Password 15 0 2 20 2F Access Password 31 16 3 30 3F Access Password 15 0 0 00 Reserved Area 0 00 0F CRC 16 1 10 1F Protocol Control Bits PC 2 20 2F EPC 95 80 3 30 3F EPC 79 64 4 40 4F EP...

Page 56: ...erminator LF Command frame for Ethernet Command frame for RS 232C Contents in command frame Contents Description Ethernet required RS 232C required Start Code SOH 0x01 Indicates the beginning of the frame with SOH No Yes Command Code Specifies the command the reader executes Yes Yes Command Data Specifies the data for use with Command Code Yes Yes FCS Stands for Frame Check Sequence hereinafter re...

Page 57: ...s Response Code Indicates the result code of command execution Yes Yes Response Data Indicates the result data of command execution Yes Yes FCS Stands for Frame Check Sequence No Yes Terminator CR 0x0d Indicates the end of the frame with CR No Yes Terminator LF 0x0a Indicates the end of the frame with LF Yes Yes Command Code Response Code Response Data LF 4 bytes 4 n 1 SOH Command Code Response Co...

Page 58: ...73 65 71 20 4D 4F 43 20 2D 61 6E 74 20 31 20 2D 74 6D 6F 20 35 30 30 FCS CR LF 31 39 0D 0A Calculation Character ASCII Code Hex Binary R 52 01010010 D 44 01000100 I 49 01001001 D 44 01000100 Space 20 00100000 2D 00101101 s 73 01110011 e 65 01100101 q 71 01110001 Space 20 00100000 M 4C 01001100 O 4F 01001111 C 43 01000011 Space 20 00100000 2D 00101101 a 61 01100001 n 6E 01101110 t 74 01110100 Space...

Page 59: ...n Reads the communication settings from the reader No SETO Set Reader Operation Sets the operation settings in the reader No GETO Get Reader Operation Reads the operation settings from reader No SAVE Save communication settings Save the communication condition into the nonvolatile memories in the reader permanent setting No 3 Control command to control the action INIT Initialize Initializes all se...

Page 60: ...n error An overrun error has occurred in one of the characters of the command frame For only RS 232C 13 00 FCS error The command frame has an incorrect FCS Only for RS 232C 0x Command code error Incorrect command has been received The response code is ICMD 1x Command parameter error Command parameter is incorrect 14 2x Command option error Command option is incorrect 0x Process error Specified com...

Page 61: ... is incorrect and command can not be executed 7B 00 Data write error During the data write into the detected tag sufficient power is not supplied to the tag 1x Antenna detection error At the R W starts up an appropriate antenna has not been connected to the specified antenna port 7C 2x Antenna error Error occurred with the antenna connected to the specified antenna port even though the antenna is ...

Page 62: ... the Command Code List of 3 1 2 Space SP Between the elements Parameters and Options space has to be entered for one or more character Even if a two or more characters of space are put in they work same way as one character space Parameter PRMx x 1 to n Mandatory for each command If there are multiple parameters in a single command they must be separated with some spaces and specified in the speci...

Page 63: ...ommand Code Set same characters specified as a command sent from the host Response Code Indicates four digit hexadecimal numbers by ASCII format Response Data DATAx x 1 to n Returns some data executed by the reader Example1 Number of tags for communication commands Example2 The tag ID s or data read by the reader with Hex code If the reader reads multiple tags IDs or data it indicates them in line...

Page 64: ...inter Data Length Write Data Lock Code Sequence seq Antenna ID ant Timeout tmo Tag Info tif Password pwd Tag Protocol ptc Read ID RDID Yes Yes Yes Yes Yes Write ID WTID Yes Yes Yes Yes Yes Yes Yes Read Data RDDT Yes Yes Yes Yes Yes Yes Yes Yes Yes Write Data WTDT Yes Yes Yes Yes Yes Yes Yes Yes Yes Lock LOCK Yes Yes Yes Yes Yes Yes Yes Kill KILL Yes Yes Yes Yes Yes Yes All options can be omitted I...

Page 65: ... in the following range in decimal format Min 1 Max 32 Note One word length is 16bits Write Data To write data into a tag with Write ID or Write Data command the data shall be specified in 32 bit hexadecimal format as below 0x not required Format XXXXXXXX XXXXXXXX X 0 to 9 A to F Ex 12345678 Lock Code When Lock command is executed this code shall be specified depending on the type of lock For GEN2...

Page 66: ...0 can t be specified on SRP MOC MRP sequence When you determine the value of Timeout see the section 5 2 Communication Time Min 0ms Max 2550ms in DRM off 10000ms in DRM on Step 10ms tmo 250 tif Tag Informatio n Specifies one or more items as additional information of tag communication results that are output in the response Specified item s shall be returned according to the specified order with c...

Page 67: ...ecified under the repeat mode SRP MRP If so the reader may freeze setting error may occur depending on the communication performance of the Ethernet or RS 232C If Ethernet s traffic is large or the communication speed setting for RS 232C is low the value shall be set longer ...

Page 68: ...ads two tags Tx RDID seq MOC ant 12 LF Rx RDID0000 002 111111111111111111111111 222222222222222222222222 LF Example 3 When MultiRepeat Antenna 1 4 read items PC EPC CRC Antenna Read count is specified the command is executed and when the reader reads a single tag Tx RDID seq MRP ant 1234 tif PER ANT CNT LF Rx RDID0000 001 3000111111111111111111111111ABCD 2 3 LF The code is returned with comma sepa...

Page 69: ...Rx WTID0000 001 444444444444444444444444 LF If tif is specified for EPC code tag s EPC data before rewritten is returned If the tag had an EPC data 444444444444444444444444 as last ID response is as above Example 3 When 1234567890ABCDEF12345678 and antenna are specified for write data and tag information the command is executed and then the reader has succeeded to write data with antenna 1 Tx WTID...

Page 70: ...and then read process has completed successfully Tx RDDT 1 0 4 LF Rx RDDT0000 001 BCAD300055555555 LF Example 3 When Memory bank 1 Start address Data pointer 2 word count to be read Data length 3 Antenna 1 to 3 Tag information EPC and antenna id is specified and read process has succeeded Tx RDDT 1 2 3 ant 123 tif EPC ANT LF Rx RDDT0000 001 111122223333 1234567890ABCDEF12345678 2 LF In this case t...

Page 71: ... 1 Start address Data pointer 3 Data 0x1234567890ABCDEF12345678 Antenna 2 and 3 Timeout 200 Tag information antenna id is specified Tx WTDT 1 3 1234567890ABCDEF12345678 ant 23 tmo 200 tif ANT LF Rx WTDT0000 001 2 LF In this case the response code has an antenna ID which is used in writing process Example 3 When specified address is not supported Tx WTDT 1 8 12345678 LF Rx WTDT0000 000 LF No count ...

Page 72: ... password 0xAAAAAAAA tag information EPC code and antenna Tx LOCK 0000 pwd AAAAAAAA tif EPC ANT LF Rx LOCK0000 001 777777777777777777777777 1 LF Example 4 When Password 0xFFFFFFFF all memories are locked permanently is set Tx LOCK 1111111111 pwd FFFFFFFF LF Rx LOCK0000 001 LF The EPC code of the tag is 1234567890ABCDEF12345678 Example 5 When Password 0x12341234 all memories are locked permanently ...

Page 73: ...g information PER and ANT is specified and KILL command has completed normally Tx KILL pwd AAAABBBB ant 3 tif PER ANT LF Rx KILL0000 001 30001234567890ABCDEF12345678ABCD 3 LF The PC code of the tag is 3000 EPC code is 1234567890ABCDEF12345678 CRC is ABCD and command executed Antenna ID is 3 Example 3 When Password 0x12345678 is specified and password data has been incorrect Tx KILL pwd 12345678 LF...

Page 74: ...ber xxxxxxxx MAC MAC address 00 00 0A 89 xx xx Reader Status Dynamic Read only GETR Code Content Variable Value ATS Antenna status Connected Antenna xxxxx x 1 to 4 ex1 All antennas are connected 1234 ex2 Antenna 1 and antenna 4 are connected 14 TTK Transition time from kick hhhh mm ss Min 00 00 00 Max 9999 59 59 Reader Settings Reader Information GETR SETR Code Content User Setting Value Factory S...

Page 75: ... Disable LIP LAN IP address IP address when using static network settings xxx xxx xxx xxx 192 168 1 200 LNM LAN subnet mask Subnet mask when using static IP address xxx xxx xxx xxx 255 255 255 0 LGW LAN default gateway Default gateway when using static IP Address xxx xxx xxx xxx 192 168 1 254 PRT Ethernet Port 3 ports are used specified port and specified port 1 and 1 Given value Min 1025 Max 6553...

Page 76: ...pace the space shall be enclosed with double quotation In a single command multiple setting items can be specified by separating with space 2 or more character spaces are acceptable for indicating separation Response SETR RC LF RC Response Code S Space Character Example 1 When DHCP Enabled is set ON Tx SETR dhe 1 LF Rx SETR0000 LF Example 2 When Host name V750 BA50C04 IP 192 168 1 1 and Subnet mas...

Page 77: ...tting item and value Note If multiple items are specified the reader shall return response with connecting specified items to the setting values with equal in the specified order Alphabetical characters included in the item name in the response shall be small characters If the setting value includes any space the space shall be enclosed with double quotation S Space Character Example 1 When Firmwa...

Page 78: ...Choice 0 1 2 3 0 SS2 Gen2 Session value 2 In case of Repeat Mode sequence Choice 0 1 2 3 2 CMD Communication mode Choice 0 Normal mode 1 Dense reader mode DRM 0 Normal mode EWL EPC word length Given value Min 0 Max 32 Step 1 0 Auto mode Communication Settings Filtering GETC SETC Code Content User Setting Value Factory Settings FTE Filtering enable Choice 0 None 1 Filter1 only 2 Filter2 only 1 2 Fi...

Page 79: ... and ft2 shall be always followed by Filtering Enable fte If you specify them in one command SETC firstly put ft1 and ft2 then fte in order If you change the filtering conditions with ft1 and or ft2 the filtering function will be temporarily Disabled If the setting item is ft1 or ft2 the five items shall be specified with space separation between each item Instead of space enclosing double quotati...

Page 80: ...RC Response Code ParamN ValueN Setting item and values Note If multiple items are specified the reader shall return response with connecting specified items to the setting values with equal in the specified order Alphabetical characters included in the item name in the response shall be small characters If the setting item is ft1 or ft2 the five items shall be returned with space separation betwee...

Page 81: ...eader If SET Communication command SETC is executed and then the reader is started up without executing this command SAVE new setting will be abandoned Command SAVE LF Note No arguments Response SAVE RC LF RC Response Code Example 1 When communication setting is saved New setting is written into the nonvolatile memory Tx SAVE LF Rx SAVE0000 LF ...

Page 82: ... ex RDID seq SOC tmo 500 Max 255 characters ASCII Note This setting value has double quotation marks None IN1 Input port 1 function setting Format Function S Timing S Command Function 0 None 1 Command execution Timing 0 Startup Fixed Command Command to be execute Ex RDID seq SOC tmo 500 Max 255 characters ASCII Note This setting value has double quotation marks Note Only when the Function is speci...

Page 83: ...eader is communicating with specified antenna 31 NML Evaluated normal completion 32 ERC Evaluated completion with error occurring OutputTime 10 to 9990 ms 0 Status kept until upcoming evaluation Note Output time is effective only for NML ERC setting Condition Note Output time is effective only for NML ERC setting Note If the condition is omitted output signal shall be on without condition Refer to...

Page 84: ...mparison symbol data is TCT 0 to 999 Logical operator AND operator Format condition A condition B OR operator Format condition A condition B If there is no condition to be set the output signal shall be on after normal end If there is no condition to be set or condition A is set condition B shall not be included in the setting Ex When the read data is 12bytes 24character and the characters from 5t...

Page 85: ... RDID ant 122322 tmo 100 LF Rx SETO0000 LF Example 4 When output 3 function setting is set as Signal is on for 2 seconds when the executed command is finished normally the read data is 12bytes 24characters and the 5th to 8th data is 0000 Tx SETO ot3 31 2000 dat 0000 LF Rx SETO0000 LF Example 5 When output 4 function setting is set as Signal is on for 1 second if tag count is 10 or less Tx SETO ot4...

Page 86: ...GETO iec LF Rx GETO0000 iec 1 RDID ant 122322 tmo 100 LF Example 2 When Input 2 function setting is never registered Tx GETO in2 LF Rx GETO0000 in2 0 0 LF Example 3 When Input 1 function setting is read Tx GETO in1 LF Rx GETO0000 in1 1 0 RDID ant 122322 tmo 100 LF Example 4 When Input 3 function setting is read but the setting is not alive Tx GETO in3 LF Rx GETO0000 in3 0 0 RDID seq MOC ant 123 LF...

Page 87: ...ory default setting All settings shall be written into the inner nonvolatile memories After executing this INIT command the reader requires reboot Command INIT LF Note No argument Response INIT RC LF RC Response Code Example 1 All setting of reader is initialized to the factory default setting Tx INIT LF Rx INIT0000 LF ...

Page 88: ...ommand STOP LF Note No arguments Response STOP RC LF RC Response Code The communication process is not running in the reader the error is returned Code 1500 Example 1 When the reader stops multi repeat communication Tx RDID seq MRP ant 12 Read ID command is started under multi repeat mode Tx STOP LF Rx STOP0000 LF ...

Page 89: ...ifying OutputSignal For OUT1 4 values are set with four characters left to the right 1 4 0 OFF 1 ON Don t care Response EXIO RC S InputSignal S OutputSignal LF RC Response Code 0000 Fixed InputSignal For IN1 4 signal values 0 or 1 are set with four characters left to the right OutputSignal For OUT1 4 signal values 0 or 1 are set with four characters left to the right 0 OFF 1 ON S Space Character E...

Page 90: ...der returns the response that the command has received When it is connected via Ethernet it is disconnect the network connection before rebooting Command REST LF Note No arguments Response REST RC LF RC Response Code Example 1 Reboot the reader Tx REST LF Rx REST0000 LF ...

Page 91: ... the reader received the command it returns the response that the command has received And the network connection is disconnected after 1 second Command GBYE LF Note No argument Response GBYE RC LF RC Response Code Example 1 Disconnect the Ethernet connection between host and the reader Tx GBYE LF Rx GBYE0000 LF ...

Page 92: ...e is no the latest response data the error is returned Code 1500 When the communication mode is SRP MRP it can be accepted However if the timeout value is small timeout interval is too short the reader can not afford to identify various responses returned continuously Example 1 When the host requests to resend the response for the successful single ID read command RDID seq SOC ant 1 tif EPC ANT th...

Page 93: ...Response TEST RC S ReaderStatus S TestData LF RC Response Code ReaderStatus Reader s status code 00 Waiting for command 10 Communicating 3x Setting error 4x System error 90 Running on Safe Mode TestData Same data as command parameter S Space Character Example 1 When test data uhf rfid is entered to check a communication status between the host and the reader Tx TEST uhf rfid LF Rx TEST0000 00 uhf ...

Page 94: ...d ch2 to ch49 and ch50 Noise level of each communication channel The response data has a noise level every 2channels 1MHz band 1ch and 2ch 3ch and 4ch 49ch and 50ch 1ch means 902 75MHz 2ch means 903 25MHz 3ch means 903 75MHz 50ch means 927 25MHz S Space Character To convert the response data to dBm put them into the following formula 20 log10 response value 135 The derived value should be used onl...

Page 95: ...to each case that rushes on conveyor in high speed Single Repeat sequence is appropriate An example command is the following Command RDID seq SRP ant 1 tmo 200 3 2 2 Example 2 To read a tag attached on various faces top face is the most to each case that passes through a gate on a conveyor the client software finds tags using 3 antennas making much of antenna 2 An example is the following Command ...

Page 96: ... each case on a pallet that passes through a gate multi repeat sequence is appropriate When the client software finds tags using 3 antennas mainly use antenna 2 an example is the following Command RDID seq MRP ant 22212223 tmo 2000 cases pallet antenna 2 antenna 1 tag antenna 3 ...

Page 97: ...t port 1 To register the command to turn on the signal of the Output port 1 when the reader reads 9 tags normally When the signal of the Output port 1 turns on blue light turns on Command to register SETO ot1 31 1000 TCT 9 Output port 2 To register the command to turn on the signal of the Output port 2 when the reader is reading tag s When the signal of the Output port 2 turns on the yellow light ...

Page 98: ...reader Light3 Red Means that read tags ware insufficient When the signal line is turn Off to On the light is turned on The signal line is connected output port 3 of the reader Communication sequence All tags are read normally Host Reader Tag In communication Tag1 Tag2 Tag3 Tag9 Tag8 Tag4 Tag5 Tag6 Tag7 Lighting Lighting Stack Lights Blue Yellow Red Response Sensor On Output port 1 Off Output port ...

Page 99: ... rapped read Buffur 5 No tag response is set SETC sbf 5 onr 1 SAVE OUT1 Data match output setting Data length is 96bit If the first data is EPC 0x30 output signal is on for 100ms SETO ot1 31 100 DAT 30 OUT2 Data unmatch output Data length is other than 96bit If the first data is not 0x30 output signal is on for 100ms SETO ot2 31 100 DAT 30 OUT3 Read result output Output signal is on for 100ms when...

Page 100: ... user A is operating via web interface and if another user B accesses to the same reader only the user B can operate it On each mode the reader has the web interface serves different functions Operation Mode Provides various functions the reader has Safe Mode Displays the reader s essential settings Update Mode Shows the process updating its firmware Explain of each mode is the following This func...

Page 101: ... command line interface Ethernet RS 232C You can go another page only when you click OK button Page Name Function Status Shows reader s information and running status Reader Settings Shows and changes reader s interface settings Reader Information Ethernet RS 232C Communication Settings Comm Settings Shows and changes communication settings RF Control Filtering Smoothing Operation Settings Shows a...

Page 102: ...a the reader has individually and flexible data changing depending on the communication status Once a communication command has been executed the Latest Communication is changed as the command is processed For example when the host sends the following command code via Ethernet port RDID ant 1 seq MRP tmo 1000 and receives response RDID0000 007 the page appears as above Page title Items Action Butt...

Page 103: ...em error occurred See below the Error code list for detail 1 TCP IP Connection Indicates TCP IP port connection status No Connection Connected Latest Communication Latest Comm Indicates Active in orange if a command is being executed Source Interface name of command execution source Ethernet RS 232C IN1 IN2 IN3 IN4 Web It indicates the current command status by using command I F Ethernet RS 232C o...

Page 104: ... Description XXX Status code YY Error type DHCP Server 31 DHCP Server error Comm Settings 33 Communication setting error Comm Settings 35 Communication setting error Operation Settings 36 Operation setting error Reader Settings 37 Reader setting error Action Reset System To reboot the system push the Reset System button After rebooting the reader you can access the browser by clicking Reload butto...

Page 105: ...105 of 135 4 2 3 Reader Settings Function In this page you can see and change the reader information Ethernet and RS 232C settings Screen Image ...

Page 106: ...255 0 Gateway The reader s Gateway address 192 168 1 254 TCP IP Port Port number of command interface 1025 to 65534 7090 RS 232C Item Description The range of the set code Default Baud Rate bps Communication speed 9600 19200 38400 57600 57600 Data Bits Communication data length 7 8 7 Parity Bit Parity bit Even Odd None Even Stop Bit s Stop bit 1 2 2 Action Save To save the setting of the reader en...

Page 107: ...is case correct the data and click Save button again 2 Can Not Connect It means that the host computer can not receive the data from the reader In this case you have to check the Ethernet connection restart the browser and then access the reader again 3 This Function is NOT Available Now It means that saving process can not be executed because of reader status ...

Page 108: ...108 of 135 4 2 4 Communication Settings Function In this page you can see and change the communication settings RF control filtering and smoothing Screen Image ...

Page 109: ...the Condition 1 Bank Communication data bit length 0 to 3 including threshold values None Pointer Comparison start point 0 to 255 including threshold values None Length Comparison bit length 1 to 255 including threshold values None Data Comparison data Data length more than 1 or more and 64 or less None Condition 2 Set value of the Condition 2 Bank Communication data bit length 0 to 3 including th...

Page 110: ... value after booting next time Errors 1 Invalid Parameter s in XXX It indicates that the data set in XXX is incorrect XXX will be one of RF Control Filtering or Smoothing In this case correct the data and click Save button again 2 Can Not Connect It means that the host computer can not receive the data from the reader In this case you have to check the Ethernet connection restart the browser and t...

Page 111: ...111 of 135 4 2 5 Operation Settings Function In this page you can see and change the operation settings command entry and programmable output Screen Image ...

Page 112: ... Programmable Output Item Description The range of the set code Default Output 1 1 Programmable output 1 settings Function Output function synchronize with this port RUN ERR COM ANT1 ANT2 ANT3 ANT 4 NML ERC None Duration ms 2 Duration for output 0 or more and less than 9990 None Condition 2 Condition for output Available only when function is NML or ERC None Output 2 Programmable output 2 settings...

Page 113: ...succeeded the label changes its color from black to blue If failed it changes to red If the process fails to complete and stops the latter item is not saved and it remains in black Errors 1 Invalid Parameter s in XXX It indicates that the data set in XXX is incorrect XXX is one of the item names In this case correct the data and click Save button again 2 Can Not Connect It means that the host comp...

Page 114: ...lly and see the response Typical options are selectable on the screen by clicking and selecting so even though users who don t know the command syntax and options well can generate command easily Also users who know them well can edit any command in the text field Screen Image ...

Page 115: ...the newer response is received it is added on the top of the data Clear To clear the response text area click Clear button then the reader clears all the data of the response text area and response counter is reset to 0001 NOTE Repeat sequence on RDID command SRP MRP is restricted on this page To try commands using repeat sequence please use another communication tool Item Options Note Command RDI...

Page 116: ...rror Logging Function The V750 reader displays error log data that includes command name and 4 digits error code after starting communication Error data is logged in order of occurrence The latest data is displayed on 01 The next one is on 02 The older data is 03 04 The data older than 32nd is abandoned Screen Image ...

Page 117: ...he latest error list or change another page you need to press Stop button When the reader is reset or powered down error log is cleared Errors 1 Can Not Connect It means that the host computer can not receive the data from the reader In this case you have to check the Ethernet connection restart the browser and then access the reader again 2 This Function is NOT Available Now It means that process...

Page 118: ...de sorted by upper two digits and their total error counts are displayed in the table The error codes that occurred once or more and their count are displayed in blue character Screen Image Action Start To display the history of error logging press Start button Then the Web page displays and updates the history for the reader s communication response While updating data you can observe the history...

Page 119: ...onitor the kinds of error occurred after the reader starts communication on real time When the reader is reset or powered down error count is cleared Errors 1 Can Not Connect It means that the host computer can not receive the data from the reader In this case you have to check the Ethernet connection restart the browser and then access the reader again 2 This Function is NOT Available Now It mean...

Page 120: ...number based on US frequency allocation 1 2 means 902 75 903 25MHz 11 12 means 907 75 908 25MHz 49 50 means 926 75 927 25MHz Screen Image Action Start To monitor noise level select antenna ID and press Start button Then the Web page displays and updates current noise level around the indicated antenna While updating data you can monitor the noise level on real time Stop To stop monitoring noise le...

Page 121: ...eceive the data from the reader In this case you have to check the Ethernet connection restart the browser and then access the reader again 2 This Function is NOT Available Now The reader is communicating with tag After stopping communication this function comes up to available ...

Page 122: ...date the firmware do the following 2 steps 2 Indicate the firmware file for V750 reader on the PC by inputting the file path in the text field or selecting the file via file dialog displayed by Browse button 3 Press Update button Then the V750 reader enters into Update Mode and starts the update process See Section 4 4 Update Mode about the process after that WARNING You must not indicate files ex...

Page 123: ...e of system error or your losing Ethernet IP address information On safe mode only status page and firmware update page are available 4 3 1 Status Page Function Shows the information of reader status Ethernet and RS 232C settings Item value is displayed as operation mode Except Firmware Version Screen Image V750 BA50D04 SG V750 BA50D04 SG 100 100 100 0 V750 BA50D04 SG Safe Mode Windows Internet Ex...

Page 124: ...face via Ethernet RS 232C Settings Operation Mode Item Description Baud Rate bps Baud rate bps Data Bits Data bit length Parity Bit Parity bit Stop Bit s Count of stop bit Action Reset System To restart the system press Reset System button After displaying message Accept RESET Reboot in one second After resetting the reader you can access the browser by clicking Reload button or opening another br...

Page 125: ...e firmware file for V750 reader on the PC by inputting the file path in the text field or selecting the file via file dialog displayed by Browse button 2 Press Update button Then the V750 reader enters into Update Mode and starts the update process See Section 4 4 Update Mode about the process after that WARNING You must not indicate files except firmware file that distributed from OMRON ...

Page 126: ... the progress status When the update process starts the V750 reader turns off all the LEDs of IN1 4 and OUT1 4 and it lights from IN1 IN2 one by one according to the status The steps may vary depending on the firmware file When all the process is finished all the LEDs of IN1 4 and OUT1 4 light Then the V750 reader restarts 3 seconds after the message signal of finishing updating WARNING Do NOT pow...

Page 127: ... after rebooting 2 File Transfer Error Please Restart System Though correct firmware file is indicated file is broken in transferring in the network Try again If update process is failed with indicating incorrect update file or another reason LED of ERR lights and web browser displays as the following The LEDs of IN1 4 and OUT1 4 maintains the status and it is not rebooted ...

Page 128: ...re no RF reflection objects around the Antenna and Tag in the measurement environment There are some areas where communication is possible outside the communications range shown in the graph by the effect of reflection off of the ground For example radio anechoic chamber Tag is OMRON Wave tag V750 D22M01 GEN2 DRM off mode The above figure of the communication range is applicable when the Short or ...

Page 129: ...ence are considered You can refer these charts on determining time out value of the reader command But you must keep in mind actual communication time on your environment may not correspond to these charts because of the reasons already described Communication Time Protocol Gen2 Sequence Multi Read Communication Mode Normal Actual Communication Time ms 150 120 90 60 30 0 Number of Tags 10 20 30 40...

Page 130: ...ication Mode Normal DRM Read Mode Communication Time Normal Mode 5ms tag DRM Mode 10ms tag EPC ID 96bits Communication Time Protocol Gen2 Sequence Single Write Communication Mode Normal DRM Write Mode Communication Time Normal Mode 60ms tag DRM Mode 100ms tag EPC ID 96bits ...

Page 131: ...131 of 135 APPENDIX OUTLINE DRAWINGS Reader Writer V750 BA50D04 SG MY Material Case Aluminum ...

Page 132: ...132 of 135 Antenna V740 HS01CA V740 HS01LA Material Case PVC Base plate Aluminum ...

Page 133: ...133 of 135 Antenna Cable V740 A01 3 0M V740 A01 10M Short cable V740 A01 3 0M Long cable V740 A01 10M Super Long cable V740 A01 20M ...

Page 134: ...134 of 135 Revision History Manual No SRFM 015 A Revision Code Date Reason for revision Revised page A 2007 11 First edition Revision Code ...

Page 135: ...317 Fax 81 3 3436 7387 Regional Headquarter OMRON ASIA PACIFIC PTE LTD Industrial Automation Business Marketing Mangement division Application Marketing Dept 438A Alexandra Road 05 05 08 Alexandra Technopark Singapre 119967 TEL 65 6835 3011 Manual No SRFM 015 A Note Specifications subject to change without notice Printed in Japan ...