3-5-8 Brake Interlock (For Motors with Brakes)
H
Magnetic Brakes
The magnetic brakes for Servomotors with brakes are specialized holding brakes with non-magnetized
operation. Therefore set the parameters so that the brake power supply is turned off after the Servomo-
tor stops. If the brake is applied while the Servomotor is operating, the brake will suffer abnormal wear or
even damage, and will quickly become defective.
For wiring methods, refer to
2-2-5 Peripheral Device Connection Examples.
H
Function
The output timing of the brake interlock signal (BKIR) that control turning the magnetic brake ON and
OFF can be set.
H
Parameters to be Set
PRM
No.
Parameter name
Factory
setting
Unit
Setting
range
Explanation
Cn-12
Brake timing 1
0
10 ms
0 to 50
Delay time setting from brake
command until servo turns off.
Cn-15
Brake command speed
100
r/min
0 to 4,500
Sets rotational speed for out-
putting brake commands.
Cn-16
Brake timing 2
50
10 ms
10 to 100
Waiting time from servo-off to
brake command output.
Operation