Regeneration Unit Specifications
H
R88A-RG08UA Regeneration Unit
D
General Specifications
Item
Standards
Operating ambient temperature
0
°
C to 55
°
C
Storage ambient temperature
–10
°
C to 75
°
C
Operating ambient humidity
35% to 85% RH (with no condensation)
Storage ambient humidity
35% to 85% RH (with no condensation)
Storage and operating
atmosphere
No corrosive gasses.
Vibration resistance
4.9 m/s
2
max.
Impact resistance
Acceleration 19.6 m/s
2
max.
D
Performance Specifications
Model
R88A-RG08UA
Regeneration operating voltage
380 V
DC
Regeneration processing current
8 A
DC
Average regeneration power
12 W (internal resistance: 50
Ω
, 60 W)
Externally connected regeneration
resistance
47
Ω
±
5%
Error detection function
Regeneration resistance disconnection, regeneration transistor
damage, overvoltage
Alarm output
SPST-NC contact (open contact at time of protective function
operation)
(200 VAC drive possible.)
External dimensions
55
×
160
×
130 (W
×
H
×
D)
D
Indicator LED Specifications
Name
Specifications
POWER
Lit while power flows between P and N terminals.
REGEN
Lit during regeneration operation.
ALARM-REGEN
Lit for regeneration resistance disconnection or regeneration transistor damage.
ALARM-OV
Lit when overvoltage occurs.
Note 1. When the error detection function operates, an alarm is output from the Unit.
Note 2. Create a sequence so that the power supply (R-T) to the Servo Driver is cut off when an alarm
is generated.
Note 3. When the error detection function operates and the Servo Driver’s power supply is cut off, the
Regeneration Unit won’t be restored to its normal status until 2 to 3 seconds have elapsed,
even if the power supply is turned on again. (Normal status is restored after the electrolytic
capacitor in the Servo Driver has been discharged and the voltage between P and N drops.)
Note 4. Does not conform to EC Directives.
Specifications