3-31
3-6-2 Jog Operations
Jog operations rotate the Servomotor in a forward or reverse direction using the Parameter Unit. Jog
operations are made possible when system check mode Cn-00 is set to “00.” The items in parentheses
in the following explanation indicate operations using the Handy-type Parameter Unit.
c n - 0 0
0 0 - 0 0
[1]
[2]
[5]
[4] ON
Data
OFF [4]
0 g
DATA
Indicates settings mode.
System check mode
H
Operating Procedure (Key in Parentheses are for Mounted-type
Parameter Units)
1. Confirm that the initial display is shown (–. bb).
2. Press the MODE/SET Key to enter the settings mode.
3. Using the Up and Down Keys, set parameter number “00.” (System check mode)
4. Press the DATA Key to display the setting of Cn-00.
5. Using the Up and Down Keys, set the parameter to “00.” (Jog operation)
6. Press the MODE/SET Key to shift to the jog display.
7. Press the SERVO (DATA) Key to turn on the servo.
8. Press the Up Key to jog forward. Forward operation will continue as long as the key is held down.
9. Press the Down Key to jog in reverse. Reverse operation will continue as long as the key is held
down.
10. Press the SERVO (DATA) Key to turn off the servo.
11. Press the MODE/SET Key to return to the data display.
12. Press the DATA Key to return to the settings mode.
H
User Parameter Settings
The rotational speed during jog operation can be set with user parameter Cn-10, as shown in the follow-
ing table.
PRM No.
Parameter name
Factory
setting
Unit
Setting range
Explanation
Cn-10
Jog speed
500
r/min
0 to 4,500
Speed setting for jog operation
Operation
Chapter 3