Power Connector Wiring Materials
Use the power supply connector that was supplied to connect the power supply to the Industrial Panel
PC.
• Select power supply conductors with consideration to the voltage drop and heat generation for the
cable length at the installation environment.
• Always use twisted wires to minimize the occurrence of electrical disturbance.
• Recommended power supply conductor sizes are provided in the table.
Wire type
Conductor cross-section
Solid conductor
0.5 to 10 mm
2
Flexible conductor
0.5 to 6 mm
2
Flexible conductor, with ferrule and no plastic sleeve
0.5 to 6 mm
2
Flexible conductor, with ferrule and plastic sleeve
0.5 to 4 mm
2
Minimum AWG according to UL/cUL
20
Maximum AWG according to UL/cUL
8
• Power Supply Connector
DC Power Supply
The OMRON S8VK-series power supply is recommended for use with the Industrial Panel PC.
Additional Information
• Refer to
on page 2 - 22 for more information.
• Refer to
4-1-3 Power Consumption Specifications
on page 4 - 3 for power consumption de-
tails.
5 Installation
5 - 35
NY-series Industrial Panel PC User's Manual (W555)
5-4
W
ire
5
5-4-3 Wire the Power Connector
Summary of Contents for NYP17-*-11 SERIES
Page 32: ...Sections in this Manual 30 NY series Industrial Panel PC User s Manual W555 ...
Page 40: ...1 Overview 1 8 NY series Industrial Panel PC User s Manual W555 ...
Page 64: ...2 Hardware 2 24 NY series Industrial Panel PC User s Manual W555 ...
Page 182: ...5 Installation 5 62 NY series Industrial Panel PC User s Manual W555 ...
Page 236: ...7 Maintenance 7 46 NY series Industrial Panel PC User s Manual W555 ...
Page 258: ...Appendices A 22 NY series Industrial Panel PC User s Manual W555 ...
Page 259: ...I Index I 1 NY series Industrial Panel PC User s Manual W555 I ...
Page 262: ......
Page 263: ......