Section 2 NS Series Functions
2-4 System Memory
2-45
NS Series Programming Manual
Bit
Function
Corresponding system memory
10 Not
used
−
9
Long Intermittent (See note 2.)
$SB14 (Long Intermittent)
8
Backlight Mode (ON: Lit, OFF:
Flashing) (See note 1.)
$SB10 (Backlight Flash Control)
7
Print Screen (See note 2.)
$SB25 (Start Printing/Capture Screen)
6 Not
used
−
5 Not
used
−
4 Not
used
−
3 Not
used
−
2 Not
used
−
1
Initialize Alarm History (See note 2.)
$SB32 (Initialize alarm/event history)
0 Not
used
−
Note 1: The operation for Backlight Mode is different if NT compatibility is not used. (The options if NT compatibil-
ity is not used are as follows: ON: Flashing, OFF: Lit.)
2: Notification will not be provided in the allocated PLC address even if the corresponding $SB is directly
manipulated. The value at the PLC address is always written to $SB.
The PT status notification allocations are shown in the following table.
Word
Function
Corresponding system memory
m
Not used (always 0)
−
m+1
PT Status Notification Bit
See the following table.
PT Status Notification Bit
Bit
Function
Corresponding system memory
15
PT Operation Status
$SB1 (RUN Signal (always ON))
14 Not
used
−
13
Battery
$SB4 (Battery voltage low notification)
12
Screen Switch Strobe
$SB2 (Screen Switch Strobe)
11 Not
used
−
10 Not
used
−
9 Not
used
−
8 Not
used
−
7
Printer Busy Status
$SB30 (Printer Busy Status/Capture Busy
Status)
6 Not
used
−
5 Not
used
−
4 Not
used
−
3 Not
used
−
2 Not
used
−
1 Not
used
−
0 Not
used
−
The window control area allocations are shown in the following table.
NS Series pop-up screens do not distinguish between global windows and local windows like the NT
Series. The pop-up screens are handled as pop-up screen 1 (k to k+2), pop-up screen 2 (k+3 to k+5),
and pop-up screen 3 (k+6 to k+8), based on the order they are opened.
Word
Function
Corresponding system memory
k
Global Window Screen No.
(See note.)
$SW1 (Current Pop-up Screen 1 Number)
k +1
Global Window X Coordinate
(See note.)
$SW2 (Position of Pop-up Screen 1
(X Coordinate))
Summary of Contents for NS10-TV Series
Page 2: ......
Page 12: ...Contents vi NS Series Programming Manual ...
Page 48: ...Section 1 Overview 1 5 Procedure before Operation 1 35 NS Series Programming Manual ...
Page 592: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual ...
Page 606: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual ...