Reference Data
The times are estimates of the device data transfer times* when using NT Links via Ethernet.
The processing times are for the following configuration and conditions.
*The transfer time is the time from when the trigger bit turns ON until the Transfer in Progress Flag
turns OFF.
PT
CJ1 PLC: Transfer Source
CJ1 PLC: Transfer Destination
•
Device data is transferred from the CJ1 PLC that is the transfer source device to the CJ1 PLC that is
the transfer destination device.
•
The transfer times are for 10 and 1,024 WORD data elements set for one group and one entry.
•
The transfer times are for when no other processing is being performed.
Connection method
10 elements
1.024 elements
1:N High-speed NT Link
723 ms
8,733 ms
Ethernet
733 ms
8,915 ms