![background image](http://html.mh-extra.com/html/omron/ns10-tv-series/ns10-tv-series_programming-manual_744520421.webp)
Section 2 NS Series Functions
2-16 Broken-line Graphs
2-372
NS Series Programming Manual
General Tab Page
Sets the display direction and gradations for broken-line graphs.
1
2
3
4
5
No. Setting
Details
1
Object Comment
Sets an explanatory comment for the pasted object (up to 32 characters).
2 Display
direction
Select a display direction of
Up
,
Down
,
Left
, or
Right
. The axis for showing the number
of graph points monitored (indicated by
a
in the diagram) and the axis for showing the
values for each graph point (indicated by
b
in the diagram) depends on the set display
direction.
•
Up
b
a
•
Down
a
b
•
Left
a
b
•
Right
a
b
Scale (Vertical)
Sets whether or not scales will be used on axes showing the number of graph points
being monitored.
No. of division
Sets the number of division between 1 and 99.
3
Scale color
Sets the scale color (from 256 available colors).
Size
Sets the length of the scale between 4 and 32 (dots).
Show Scale Line
Sets whether or not to display the scale.
Line style
Select from the five line types listed below.
Solid line, dotted line, broken line, 1-dot chain line, or 2-dot chain line
Indirect reference of
showing scale line
If this option is selected the scale is displayed when the specified address is ON.
Scale (Horizontal)
Sets whether or not scales will be used on axes showing the number of graph points.
No. of division
Sets the number of division between 1 and 99.
4
Scale color
Sets the scale color (from 256 available colors).
Size
Sets the length of the scale between 4 and 32 (dots).
Show Scale Line
Sets whether or not to display the scale.
Line style
Select from the five line types listed below.
Solid line, dotted line, broken line, 1-dot chain line, or 2-dot chain line
Indirect reference of
showing scale line
If this option is selected the scale is displayed when the specified address is ON.
Display update
The broken-line graph display can be updated (refreshed).
Specify display Update
bit
Normally, the display is updated whenever a value changes.
If
Specify display update bit
is selected, the display will be updated only when the
specified address turns ON.
5
Specify the No. of
points shown
The number of bits from the beginning that will be displayed can be specified.
Summary of Contents for NS10-TV Series
Page 2: ......
Page 12: ...Contents vi NS Series Programming Manual ...
Page 48: ...Section 1 Overview 1 5 Procedure before Operation 1 35 NS Series Programming Manual ...
Page 592: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual ...
Page 606: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual ...