![background image](http://html.mh-extra.com/html/omron/ns10-tv-series/ns10-tv-series_programming-manual_744520488.webp)
Section 2 NS Series Functions
2-20 Special Functions
2-439
NS Series Programming Manual
Select Operation Log
Setting.
Select
CIO 0.0
.
4. Setting Dialog Box will be displayed.
Select the
Record to Operation Log
Check Box.
Input Automatic Switch into the
Message
Field, and then click the OK Button.
Select
Record to Operation Log
.
Input
Automatic Switch
.
5. Use the same procedure to set the operation log for CIO0.1.
Select
Record to Operation Log
.
Input
Manual Switch
.
6. Create a Multifunction Object on any screen and make the following settings.
Execution timing
Function
Label
When pressing
Switch Screen –
System Menu Display –
Operation Log (Sort by
Occurrence)
Operation Log Display
7. In the same way, create a Multifunction Object and make the following setting
Execution timing
Function
Label
When pressing
Special – Operation
Log Control –
Operation Log Save.
Operation Log Save
8. Transfer this project to the NS-series PT.
Operation with the NS-series PT
1. Start the NS-series PT that includes the project created above.
2. Turn ON $SB39.
3. The status of CIO 0.0 and CIO 0.1 (ON and OFF for the automatic switch and manual switch) will
be registered in the operation log.
Summary of Contents for NS10-TV Series
Page 2: ......
Page 12: ...Contents vi NS Series Programming Manual ...
Page 48: ...Section 1 Overview 1 5 Procedure before Operation 1 35 NS Series Programming Manual ...
Page 592: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual ...
Page 606: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual ...