Section 2 NS Series Functions
2-5 Communications Address Settings
2-53
NS Series Programming Manual
N
N
N
o
o
o
t
t
t
e
e
e
♦
The following restrictions apply to symbol names.
•
A number cannot be used for the symbol’s first character.
•
The following symbols cannot be used. (The underscore character (_) can be used.)
[!] [”] [$] [%] [&] [’] [(] [)] [-] [=] [^] [~] [|] [@] [`] [[] [{] [;] [+] [:] [*] [] ] [] ] [,] [<] [.] [>] [/] [?]
If the project version is lower than version 8.0, [#] and [\] cannot be used in addition to the symbols
given above.
•
Spaces cannot be used.
•
Addresses cannot be used as names.
•
The maximum length of the symbol name is 64 characters.
2-5-4 Tags
Format
Tags are specified in the following format.
Host name:Tag name
Example: HOST1:Lamp1
For array variables, specify tags using the following format.
Host name:Tag name[index]
Example: HOST1:WORD[0] (Specifies the first element of an array called WORD.)
N
N
N
o
o
o
t
t
t
e
e
e
♦
Bit positions cannot be specified using tags.
♦
Structured variables are not supported.
Creating Tags
The following methods can be used to create tags.
•
Copying from the CX-Programmer’s symbol table.
•
Registering new tags in the symbol table.
•
Inputting new tags for a communications address in the Address Setting Dialog Box.
•
Directly inputting new tags for a communications address.
N
N
N
o
o
o
t
t
t
e
e
e
♦
If tags are used, they must have the data types and names as the corresponding network variable in
the host (PLC). Therefore, we recommend that you copy tags from the CX-Programmer’s symbol
table.
♦
STRING variables and array variables cannot be created with the CX-Designer.
♦
CX-Designer version 3.2 or higher and CX-Programmer version 9.2 or higher are required to copy data
structures.
Copying from the Symbol Table of the CX-Programmer
Use the following procedure to copy tags from the CX-Programmer’s symbol tables.
1. Select the network variable to be reused in the CX-Programmer’s symbol table.
Summary of Contents for NS10-TV Series
Page 2: ......
Page 12: ...Contents vi NS Series Programming Manual ...
Page 48: ...Section 1 Overview 1 5 Procedure before Operation 1 35 NS Series Programming Manual ...
Page 592: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual ...
Page 606: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual ...