![background image](http://html1.mh-extra.com/html/omron/g3pw/g3pw_user-manual_742699039.webp)
24
Installation
Section 3-2
Mounting Screws
Control Panel Ventilation
The G3PW Power Controller generates a lot of heat and it uses natural heat
convection for cooling. Mounting the Power Controller in the wrong direction
may obstruct heat radiation and cause malfunctions or accidents. To increase
cooling efficiency, mount the Power Controller in the correct direction and take
control panel ventilation and the installation location into consideration to
avoid obstructing heat dissipation.
■
G3PW-A260
100 min.
176
±
0.2
Two, M5
57.6
±
0.2
90 min.
Model
Tightening torque
Screw size
All models
2.3 to 2.5 N·m
M5, length: 10 mm min.