85
Echo-back Test
Section 6-10
6-10 Echo-back Test
This command performs an echo-back test.
Command
Response
1. Test Data
The test data can contain up to 200 (00C8H) bytes.
Set the test data within the following ranges according to the communications
data length setting.
2. Response Codes
Example:
Command: [STX]010000801123[ETX][BCC]
Response: [STX]01000008010000123[ETX][BCC]
"08"
Test Data
MRC
2
SRC
2
0 to 200
"01"
"08"
MRC
2
SRC
2
Response code
4
0 to 200
"01"
Test Data
Data length
Test data
7 bits
ASCII 20H to 7EH
8 bits
ASCII 20H to 7EH or A1H to FEH
Response code
Error name
Cause
“1001”
Command length too long
The command is too long.
“0000”
Normal end
Processing was completed
normally.