QUICK START GUIDE

Applicable Model: EC16  &  DEX16

Version: 1.0
Date: March 2023

Elevator Control Panel &
Elevator Floor Expansion Board

Summary of Contents for EC16

Page 1: ...QUICK START GUIDE ApplicableModel EC16 DEX16 Version 1 0 Date March 2023 ElevatorControlPanel ElevatorFloorExpansionBoard...

Page 2: ...disk upgrade 5 to 10 seconds to restart the controller 10 seconds or more to restore the factory settings When restoring the factory settings only the network configuration of the device is restored...

Page 3: ...icator green Slowly flashing Green LED indicates normal working status of the system PWR indicator red Solid Red LED indicates normal energization 2 LED indicators on the Elevator master controller pa...

Page 4: ...aker Voice Tamper Switch FIRE Emergency Button No Manual Button Power Input Reset Button U Disk Interface TCP IP Reader Interface LAN2 Ethernet Interface LAN1 10 10 10 10 10 13 14 15 16 17 10 10 10 10...

Page 5: ...ayers of extended output F17 32 Elevator Keys Bus PC Power In TCP IP EC16 DEX16 16 15 2 1 32 31 18 17 Elevator operation panel Alarm RS 485 FIRE D147 Card Issuer TCP IP Switch F1 16 Elevator Cabs 4 Sy...

Page 6: ...following the order in which each DEX16 is connected 4 The DIP switch needs to be set with the control board powered o and takes e ect after restart After setting the DIP switch does not need to be s...

Page 7: ...n Instruction Elevator Logic Controller S2 S1 COM NO NC Elevator Logic Controller Elevator Button Elevator Button Original Elevator Button Connection Elevator Button Connection for Elevator Control In...

Page 8: ...5 255 0 DC12V EC16 Elevator Controller TCP IP ZKBio CVSecurity FR1500 KR600 RS 485 Wiegand 3 Each EC16 can connect a maximum of eight RS 485 readers and twoWiegand readers 1 The readers can be connect...

Page 9: ...3 4 5 6 4 Click Add after the controller in the operationbar to add the device 5 After setting the relevant parameters click OK to finish adding the elevator controller 6 Click Close to close the Devi...

Page 10: ...New to add a new elevator control level group 3 Enter the level name time zones and setting area then click OK to confirm and exit 4 After adding successfully check the levels group 5 Click Add Floor...

Page 11: ...the selected column on the right 2 Check the levels group and click the Add Personnel icon in its bar to open the settings window a Set Access By Levels 1 Click Elevator Elevator Control Rule Set Acc...

Page 12: ...selected column on the right c Set Access By Department 1 Click Elevator Elevator Control Rule Set Access By Department to enter the setting interface 2 Check the department and click the Add to Defa...

Page 13: ...ZKTeco Industrial Park No 32 Industrial Road TangxiaTown Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2023ZKTECOCO LTD AllRightsReserved...