Appendix B
Troubleshooting
56
Error
Remedy
Description
Expansion
Master
Master
T/R
RDY
ALM
NODE
END
T/R
T/R
RDY
RDY
Errors
before
normal
operation
f
f
Y
X
Y
––
f
Y
Input/output type of
Master/Expansion Master
differs from input/output type of
the corresponding Slave.
Match input/output type of
Master/Expansion Master to
input/output type of the
corresponding Slave.
Expansion Masters exist with
different input/output type but
duplicate unit #.
Expansion Masters exist with
different input/output type but
duplicate Slave address.
Correct settings to give unique
unit # and Slave address.
A 4-point unit is set between
#24 and #27.
The #24 to #27 area is
reserved for 8-point and
16-point units. Set 4-point units
between #0 and #23.
Transmission to Slaves whose
addresses are set correctly is possible
for this display status. Slaves with errors
can be identified by checking the T/R
indicators, which will be lit on Slaves
with errors.
The Slave address of an
8-point unit is set to an odd
value between #0 and #23.
The Slave address of a
16-point unit is set to an odd
value between #0 and #27.
Refer to Word Allocations and
correct the Slave address.
Duplicate bit addresses set for
4-, 8-, and 16-point units.
Errors
after
normal
f
X
f
X
––
––
f
fY
Transmission path shorted.
Transmission path
discontinuity.
Correctly wire the transmission
path.
operation
X
Power off at Slave.
Turn on the Slave power
supply.
Slave CPU out of control
Turn Slave power off and back
on. Replace Slave if same error
re-occurs.
f
f
Y
X
X
f
f
Y
Error occurred in the output of
a Slave with error detection
function.
Replace defective relay or
normally return load line.
Note The error check shown in the table above is conducted when the CQM1H/CQM1 is turned on (even if the
CQM1H/CQM1 is not in RUN mode). The indicator display on the CQM1H/CQM1 CPU is unrelated to the
indicator display on the G730 Interface Unit.
System Error
The error shown below is a CQM1H/CQM1 error which prevents CQM1H/CQM1 operation.
Error
Description
Cause
Remedy
I/O Unit
overflow
An I/O overflow error occurred
in the CPU.
The total number of I/O words in
the system exceeds the
maximum I/O words of the CPU.
Correct the system, referring to
1-2 System Configuration and
4-1 Word Allocation.
Operation Flowchart and Indicator Status
The indicator status are shown below after CQM1H/CQM1 power on, during normal operation, and after an error.
Status
Master
Expansion
Master
RDY
T/R
RDY
T/R
END
NODE
ALM
RDY
T/R
CQM1H/CQM1 power on
X
X
X
X
X
X
X
X
CQM1H/CQM1 initial check OK
f
X
Y
f
X
X
f
X
G730 transmission line check – terminator found
f
*
f
*
Y
*
X*
X*
X*
f
*
Y
*
Note *Normal operation status
Summary of Contents for CQM1H - 08-2005
Page 1: ...Cat No W238 E1 8 Dedicated I O Units CQM1H CQM1 series OPERATION MANUAL SYSMAC ...
Page 2: ......
Page 3: ...CQM1H CQM1Series Dedicated I O Units Operation Manual Revised August 2000 ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 21: ...1 PART I B7A Interface Unit CQM1 B7A02 CQM1 B7A03 CQM1 B7A12 CQM1 B7A13 CQM1 B7A21 ...
Page 22: ......
Page 42: ......
Page 45: ...25 PART II G730 Interface Unit CQM1 G7M21 CQM1 G7N01 CQM1 G7N11 ...
Page 46: ......
Page 62: ......
Page 72: ......
Page 74: ...Appendix A Specifications 54 Dimensions Common for Master and Expansion Master Unit mm ...
Page 78: ......
Page 79: ...59 PART III I O Link Unit CQM1 LK501 ...
Page 80: ......
Page 88: ......
Page 92: ......
Page 93: ...73 PART IV Analog Input Unit and Analog Power Supply Units CQM1 AD041 CQM1 IPS01 CQM1 IPS02 ...
Page 94: ......
Page 118: ......
Page 120: ......
Page 121: ...101 PART V Analog Output Unit and Analog Power Supply Units CQM1 DA021 CQM1 IPS01 CQM1 IPS02 ...
Page 122: ......
Page 126: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 156: ......
Page 172: ......
Page 186: ......
Page 187: ...167 PART VII Linear Sensor Interface Units CQM1 LSE01 CQM1 LSE02 ...
Page 188: ......
Page 192: ......
Page 204: ......
Page 218: ......
Page 238: ......
Page 242: ......
Page 246: ......
Page 248: ......
Page 250: ......