34
2-1
Nomenclature
CQM1-G7M21 Master
Front View
Terminal screws: M3
(Optimum tightening torque: 0.5 N
S
m)
Transmission terminal
(Refer to 3-1 Transmission Cables)
For connection of transmission
cable to Expansion Master or
Slave.
Indicators (see following table)
ALM output terminals
(Refer to 3-2 External Output
Connection Cables)
Terminals shorted if an error oc-
curs in the output of a unit with
error detection function
(G730-ROC04-A).
Transmission Ready terminals
(Refer to 3-2 External Output
Connection Cables)
Terminals shorted while in trans-
mission status with power on.
Read signal at CPU and confirm
transmission ready status be-
fore enabling data.
Refer to 4-2 Handling Power
On. The output from these ter-
minals linked to ON/OFF status
of the T/R RDY indicator.
+
–
Name
Color
Function
RDY
Unit Ready
Green
Lit when power is on and if
CQM1H/CQM1 recognizes a Master.
IN 1CH
IN Mode
Orange
Lit while number of inputs set to 1
word (16 points). Not lit when set to 2
words (32 points).
OUT 1CH
OUT Mode
Orange
Lit while number of outputs set to 1
word (16 points). Not lit when set to 2
words (32 points).
T/R RDY
Transmission
Ready
Green
Lit while in transmission status with
power on. Not lit while in transmission
error.
HOLD
HOLD Setting
Orange
Lit while DIP switch set to HOLD (data
held when a transmission error
occurs).
T/R
Transmitting
Red
Flashes while searching for terminator
or during transmission with power
turned on. Lit when there is a
transmission error. Not lit when there
is an error in the Master.
END
Terminator
Red
Lit when the power is turned on. Goes
out when the terminator is found.
Flashes when multiple terminators are
present.
NODE
Slave Setting
Error
Red
Lit when Slave set to #28 to #30.
Flashes for other address setting error
(refer to Appendix B Troubleshooting
for details).
ALM
Slave Alarm
Red
Lit after error occurs with Slave output
(G730-ROC04-A).
Indicators
Nomenclature
Section 2-1
Summary of Contents for CQM1H - 08-2005
Page 1: ...Cat No W238 E1 8 Dedicated I O Units CQM1H CQM1 series OPERATION MANUAL SYSMAC ...
Page 2: ......
Page 3: ...CQM1H CQM1Series Dedicated I O Units Operation Manual Revised August 2000 ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 21: ...1 PART I B7A Interface Unit CQM1 B7A02 CQM1 B7A03 CQM1 B7A12 CQM1 B7A13 CQM1 B7A21 ...
Page 22: ......
Page 42: ......
Page 45: ...25 PART II G730 Interface Unit CQM1 G7M21 CQM1 G7N01 CQM1 G7N11 ...
Page 46: ......
Page 62: ......
Page 72: ......
Page 74: ...Appendix A Specifications 54 Dimensions Common for Master and Expansion Master Unit mm ...
Page 78: ......
Page 79: ...59 PART III I O Link Unit CQM1 LK501 ...
Page 80: ......
Page 88: ......
Page 92: ......
Page 93: ...73 PART IV Analog Input Unit and Analog Power Supply Units CQM1 AD041 CQM1 IPS01 CQM1 IPS02 ...
Page 94: ......
Page 118: ......
Page 120: ......
Page 121: ...101 PART V Analog Output Unit and Analog Power Supply Units CQM1 DA021 CQM1 IPS01 CQM1 IPS02 ...
Page 122: ......
Page 126: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 156: ......
Page 172: ......
Page 186: ......
Page 187: ...167 PART VII Linear Sensor Interface Units CQM1 LSE01 CQM1 LSE02 ...
Page 188: ......
Page 192: ......
Page 204: ......
Page 218: ......
Page 238: ......
Page 242: ......
Page 246: ......
Page 248: ......
Page 250: ......