11
CQM1-B7A13
Front View
Indicators (see following table)
B7A Link Terminal connection terminals 1
For connection of a 16-point Input B7A Link Terminal.
Inputs least-significant word (n) data.
External power terminals
Required for transmission with the B7A Link Terminal. Con-
nect a 12- to 24-VDC power supply.
Terminal screws: M3
(Optimum tightening torque: 0.5 N
S
m)
B7A Link Terminal connection terminals 2
For connection of a 16-point Input B7A Link Terminal.
Inputs most-significant word (n+1) data.
Name
Color
Function
RDY
Unit ready
Green
Lit while the CQM1H/CQM1 is supplied
with power.
3ms
Transmission
delay time
Orange
Lit while transmission delay time is set
to RAPID (3 ms). Not lit when set to
STANDARD (19.2 ms).
LOAD OFF
Transmission
error
processing
Orange
Lit while transmission error processing
is set to LOAD OFF. Not lit when set to
HOLD.
15IN+ERR
Input mode
Orange
Lit while input mode is set to 15IN+ERR.
Not lit when set to 16IN.
ERR1
Input 1
transmission
error
Red
Lit when normal transmission with the
Input B7A Link Terminal connected to
connection terminals 1 is not possible or
when no Input B7A Link Terminal is
connected.
ERR2
Input 2
transmission
error
Red
Lit when normal transmission with the
Input B7A Link Terminal connected to
connection terminals 2 is not possible or
when no Input B7A Link Terminal is
connected.
Indicators
Nomenclature
Section 2-1
Summary of Contents for CQM1H - 08-2005
Page 1: ...Cat No W238 E1 8 Dedicated I O Units CQM1H CQM1 series OPERATION MANUAL SYSMAC ...
Page 2: ......
Page 3: ...CQM1H CQM1Series Dedicated I O Units Operation Manual Revised August 2000 ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 21: ...1 PART I B7A Interface Unit CQM1 B7A02 CQM1 B7A03 CQM1 B7A12 CQM1 B7A13 CQM1 B7A21 ...
Page 22: ......
Page 42: ......
Page 45: ...25 PART II G730 Interface Unit CQM1 G7M21 CQM1 G7N01 CQM1 G7N11 ...
Page 46: ......
Page 62: ......
Page 72: ......
Page 74: ...Appendix A Specifications 54 Dimensions Common for Master and Expansion Master Unit mm ...
Page 78: ......
Page 79: ...59 PART III I O Link Unit CQM1 LK501 ...
Page 80: ......
Page 88: ......
Page 92: ......
Page 93: ...73 PART IV Analog Input Unit and Analog Power Supply Units CQM1 AD041 CQM1 IPS01 CQM1 IPS02 ...
Page 94: ......
Page 118: ......
Page 120: ......
Page 121: ...101 PART V Analog Output Unit and Analog Power Supply Units CQM1 DA021 CQM1 IPS01 CQM1 IPS02 ...
Page 122: ......
Page 126: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 156: ......
Page 172: ......
Page 186: ......
Page 187: ...167 PART VII Linear Sensor Interface Units CQM1 LSE01 CQM1 LSE02 ...
Page 188: ......
Page 192: ......
Page 204: ......
Page 218: ......
Page 238: ......
Page 242: ......
Page 246: ......
Page 248: ......
Page 250: ......