131
Name
Color
Function
OPERATION
Orange
Lit when the control output of the sensor module
specified with the module selector is ON.
STABILITY
Green
Lit when the operation of the sensor module
specified with the module selector is stable.
TEACHING
Red/Green
Indicates the teaching status of sensitivity setting.
Features
•
The module selected is set to the operation monitor mode or teaching mode
using the mode setting selector of the CQM1-TU001.
•
When the CQM1-TU001 is in operation monitor mode, the operation of the
module selected with the module selector of the CQM1-TU001 can be moni-
tored with the operation indicator and stability operation indicator of the
CQM1-TU001.
•
When the module selector is set to the 0, module 0 will be selected. Slide the
module selector and set to 1 for module 1, 2 for module 2, and 3 for module 3.
•
Set the mode setting selector to SET before setting the Sensor Unit to the
teaching mode and set the mode setting selector to RUN before setting the
Sensor Unit to the operation monitor mode.
Sensor Unit
The READY indicator (green) is lit when the I/O bus of the CQM1-SEN01 is
ready to retrieve signals after the CQM1-SEN01’s address is set properly with
the CPU. The output indicators (orange) are lit according to the operation of
each module inserted to slots 0 to 3 of the CQM1-SEN01.
Remote Console
•
The stability operation indicator (green) and operation indicator (orange) of the
CQM1-TU001 correspond to the stability operation indicator (green) and op-
eration indicator (orange) of each sensor module.
•
The teaching indicator (red/green) on the CQM1-TU001 is used as a teaching
monitor for the module selected.
•
The operation indicator is lit when a sensing object is within the sensing dis-
tance and the object will be detected. The stability operation indicator shows
the stability of detecting or non-detecting operations. The stability operation
indicator will be lit when a sensing object is located 0.93 times as near as the
sensing distance or less. The stability operation indicator will be also lit when a
sensing object is located 1.07 times as far as the sensing distance or more.
Operation indica-
tor (orange)
Stability operation
indicator
Stable non-
sensing zone
Stable sens-
ing zone
OFF
ON
Setting distance
x
approx. 1.07
Setting distance
Setting distance
x
approx. 0.93
ON
OFF
ON
Indicators
Nomenclature
Section 2-1
Summary of Contents for CQM1H - 08-2005
Page 1: ...Cat No W238 E1 8 Dedicated I O Units CQM1H CQM1 series OPERATION MANUAL SYSMAC ...
Page 2: ......
Page 3: ...CQM1H CQM1Series Dedicated I O Units Operation Manual Revised August 2000 ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 21: ...1 PART I B7A Interface Unit CQM1 B7A02 CQM1 B7A03 CQM1 B7A12 CQM1 B7A13 CQM1 B7A21 ...
Page 22: ......
Page 42: ......
Page 45: ...25 PART II G730 Interface Unit CQM1 G7M21 CQM1 G7N01 CQM1 G7N11 ...
Page 46: ......
Page 62: ......
Page 72: ......
Page 74: ...Appendix A Specifications 54 Dimensions Common for Master and Expansion Master Unit mm ...
Page 78: ......
Page 79: ...59 PART III I O Link Unit CQM1 LK501 ...
Page 80: ......
Page 88: ......
Page 92: ......
Page 93: ...73 PART IV Analog Input Unit and Analog Power Supply Units CQM1 AD041 CQM1 IPS01 CQM1 IPS02 ...
Page 94: ......
Page 118: ......
Page 120: ......
Page 121: ...101 PART V Analog Output Unit and Analog Power Supply Units CQM1 DA021 CQM1 IPS01 CQM1 IPS02 ...
Page 122: ......
Page 126: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 156: ......
Page 172: ......
Page 186: ......
Page 187: ...167 PART VII Linear Sensor Interface Units CQM1 LSE01 CQM1 LSE02 ...
Page 188: ......
Page 192: ......
Page 204: ......
Page 218: ......
Page 238: ......
Page 242: ......
Page 246: ......
Page 248: ......
Page 250: ......