Appendix A
Specifications
158
E3C-MA11 Photoelectric Module
Item
Rating
Power supply voltage
9 VDC (supplied from Sensor Unit)
Current consumption
50 mA max.
Response time
1.5 ms max.
Timer function
10-ms OFF-delay timer (see note)
Indicators
Operation indicator (orange) and stability operation indicator (green)
Teaching monitor
Indicators (operation indicator and stability operation indicator are
used)
Output mode
Light ON and Dark ON (selectable)
Dimension (mm)
28.1
×
17.8
×
62.1 (W
×
H
×
D)
Weight
26 g
Note The 10-ms OFF-delay timer function can be turned OFF.
E2C-MA11 Proximity Sensor Module
Item
Rating
Power supply voltage
9 VDC (supplied from Sensor Unit)
Current consumption
50 mA max.
Sensing dis-
tance ad-
Setting for Teaching
without Sensing Object
E2C-CR5B
E2C-CR8A
E2C-CR8B
E2C-X1A
E2C-C1A
E2C-X1R5A
justment
(see note 2)
0.45 mm min.
0.72 mm min.
0.9 mm min.
1.35 mm min.
range (see
note 1)
Setting for Teaching
with Sensing Object
and Teaching for Posi-
tion Control
0.1 to 0.7 mm
0.16 to 1.2 mm
0.2 to 1.5 mm
0.3 to 2 mm
Temperature influence
±
25% max. of
sensing distance
at 23
°
C between
0 and 55
°
C
±
10% max. of sensing distance at 23
°
C between 0 and
55
°
C
Differential travel
15% max. of rated
sensing distance
10% max. of rated sensing distance
Response delay
Refer to the response frequency for the proximity sensor
Output type
NO (ON when sensing object detected)
Timer functions
Off-delay timer fixed at 10 ms (see note 3)
Cable length compensation
Mode set via four ganged switches
Indicators
Operation indicator (orange) and stability indicator (green)
Teaching monitor
Indicator (orange/green indicator: operation, using stability indicator)
Dimension (mm)
28.1
×
17.8
×
62.1 (W
×
H
×
D)
Weight
26 g
Note 1. Perform positioning teaching within the stable sensing range. Even if teaching is performed successfully
outside the stable sensing range, the E2C-MA11 in operation may not reset properly. Furthermore, even
if teaching is performed successfully with or without a sensing object, the E2C-MA11 may not reset prop-
erly after a delicate change is detected.
2. With no surrounding metal or background objects.
3. Off-delay timer can also be turned off with a switch.
Summary of Contents for CQM1H - 08-2005
Page 1: ...Cat No W238 E1 8 Dedicated I O Units CQM1H CQM1 series OPERATION MANUAL SYSMAC ...
Page 2: ......
Page 3: ...CQM1H CQM1Series Dedicated I O Units Operation Manual Revised August 2000 ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 21: ...1 PART I B7A Interface Unit CQM1 B7A02 CQM1 B7A03 CQM1 B7A12 CQM1 B7A13 CQM1 B7A21 ...
Page 22: ......
Page 42: ......
Page 45: ...25 PART II G730 Interface Unit CQM1 G7M21 CQM1 G7N01 CQM1 G7N11 ...
Page 46: ......
Page 62: ......
Page 72: ......
Page 74: ...Appendix A Specifications 54 Dimensions Common for Master and Expansion Master Unit mm ...
Page 78: ......
Page 79: ...59 PART III I O Link Unit CQM1 LK501 ...
Page 80: ......
Page 88: ......
Page 92: ......
Page 93: ...73 PART IV Analog Input Unit and Analog Power Supply Units CQM1 AD041 CQM1 IPS01 CQM1 IPS02 ...
Page 94: ......
Page 118: ......
Page 120: ......
Page 121: ...101 PART V Analog Output Unit and Analog Power Supply Units CQM1 DA021 CQM1 IPS01 CQM1 IPS02 ...
Page 122: ......
Page 126: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 156: ......
Page 172: ......
Page 186: ......
Page 187: ...167 PART VII Linear Sensor Interface Units CQM1 LSE01 CQM1 LSE02 ...
Page 188: ......
Page 192: ......
Page 204: ......
Page 218: ......
Page 238: ......
Page 242: ......
Page 246: ......
Page 248: ......
Page 250: ......