189
5-2
Programming Console Operation
Refer to the CQM1H Operation Manual (W363) or the CQM1 Operation Manual
(W226) for the detailed operating method of the Programming Console.
The operation of the Programming Console required for the initial settings is ex-
plained below.
Initial Screen
Operate the Programming Console as described below so that the default
screen of the Programming Console in program mode will appear.
1, 2, 3...
1. Connect the Programming Console to the CQM1H/CQM1 CPU, set the
mode selector of the Programming Console to PROGRAM MODE, and sup-
ply power to the Programming Console.
<Program>
Password
2. Input the password.
CLR
MONTR
<Program>
3. The default screen will appear.
CLR
00000
I/O Words
The contents of the I/O words will appear on the screen of the Programming
Console. When measured mode is selected for data input, the present binary-
coded scaled conversion data will appear under the input word display.
1, 2, 3...
1. The input word (word 001 in this example) will be displayed.
SHIFT
*
CH
A
0
A
0
B
1
MONTR
c001
0000
2. The output word (word 100 in this example) will be displayed.
SHIFT
*
CH
B
1
A
0
A
0
MONTR
c100 c001
0000 0000
Output word
Input word
Command
The command codes can be set to output word. In this example, descriptions are
given for the operation mode A.
1, 2, 3...
1. The command code is set to the output word. The response for the com-
mand will appear under the input word display.
CHG
SHIFT
C
2
C
A
0
A
0
A
0
WRITE
c100 c001
C000 C000
2. If any parameter is used, the contents of the output word will be replaced
with the parameter. The response to the parameter will appear under the
input word display.
CHG
C
2
C
2
D
3
B
1
WRITE
c100 c001
2231 2231
Programming Console Operation
Section 5-2
Summary of Contents for CQM1H - 08-2005
Page 1: ...Cat No W238 E1 8 Dedicated I O Units CQM1H CQM1 series OPERATION MANUAL SYSMAC ...
Page 2: ......
Page 3: ...CQM1H CQM1Series Dedicated I O Units Operation Manual Revised August 2000 ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 21: ...1 PART I B7A Interface Unit CQM1 B7A02 CQM1 B7A03 CQM1 B7A12 CQM1 B7A13 CQM1 B7A21 ...
Page 22: ......
Page 42: ......
Page 45: ...25 PART II G730 Interface Unit CQM1 G7M21 CQM1 G7N01 CQM1 G7N11 ...
Page 46: ......
Page 62: ......
Page 72: ......
Page 74: ...Appendix A Specifications 54 Dimensions Common for Master and Expansion Master Unit mm ...
Page 78: ......
Page 79: ...59 PART III I O Link Unit CQM1 LK501 ...
Page 80: ......
Page 88: ......
Page 92: ......
Page 93: ...73 PART IV Analog Input Unit and Analog Power Supply Units CQM1 AD041 CQM1 IPS01 CQM1 IPS02 ...
Page 94: ......
Page 118: ......
Page 120: ......
Page 121: ...101 PART V Analog Output Unit and Analog Power Supply Units CQM1 DA021 CQM1 IPS01 CQM1 IPS02 ...
Page 122: ......
Page 126: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 156: ......
Page 172: ......
Page 186: ......
Page 187: ...167 PART VII Linear Sensor Interface Units CQM1 LSE01 CQM1 LSE02 ...
Page 188: ......
Page 192: ......
Page 204: ......
Page 218: ......
Page 238: ......
Page 242: ......
Page 246: ......
Page 248: ......
Page 250: ......