141
3-3
Connection of CQM1-TU001 Remote Console
•
Remove the cover of the Unit and insert the console plug into the console con-
nector of the Unit so that the polarity of the console plug and the console con-
nector will match.
•
The console connector does not incorporate a lock mechanism. To disconnect
the console plug, hold the console plug and pull it straight out.
•
It is not possible to mount the cover to the Unit if the console plug is connected
to the console connector.
•
The console plug can be disconnected from the console connector even if the
Unit is turned on. Do not, however, disconnect the console plug while the sen-
sitivity of the Unit is being adjusted.
3-4
Connection of a Variety of Sensors
3-4-1 E3X-MA11 Optical Fiber Photoelectric Module
Connecting Fibers
Set the fiber lock lever of the E3X-MA11 to FREE before inserting an optical fiber
cable to a fiber insertion mouth of the E3X-MA11 as shown in the following il-
lustration.
After inserting two optical fiber cables from the Fiber Units to the fiber insertion
mouths of the E3X-MA11, set the fiber lock lever to LOCK to secure the optical
fiber cables.
Insertion mark
Insert the optical fiber cables into the E3X-MA11 before mounting the E3X-MA11
to the Sensor Unit.
Note If the tips of the two optical fiber cables are not inserted into the E3X-MA11 to the
insertion marks, the sensing distance may be reduced.
Disconnecting Fibers
To disconnect the optical fiber cables from the E3X-MA11, hold and pull out the
optical fiber cables carefully. Before disconnecting the optical fiber cables from
the E3X-MA11, be sure to set the fiber lock lever to FREE.
Note If the optical fiber cables are disconnected without setting the fiber lock lever to
FREE, the optical fiber cables may break and the E3X-MA11 may malfunction
due to fragments of broken optical fiber cables.
Connection of a Variety of Sensors
Section 3-4
Summary of Contents for CQM1H - 08-2005
Page 1: ...Cat No W238 E1 8 Dedicated I O Units CQM1H CQM1 series OPERATION MANUAL SYSMAC ...
Page 2: ......
Page 3: ...CQM1H CQM1Series Dedicated I O Units Operation Manual Revised August 2000 ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 21: ...1 PART I B7A Interface Unit CQM1 B7A02 CQM1 B7A03 CQM1 B7A12 CQM1 B7A13 CQM1 B7A21 ...
Page 22: ......
Page 42: ......
Page 45: ...25 PART II G730 Interface Unit CQM1 G7M21 CQM1 G7N01 CQM1 G7N11 ...
Page 46: ......
Page 62: ......
Page 72: ......
Page 74: ...Appendix A Specifications 54 Dimensions Common for Master and Expansion Master Unit mm ...
Page 78: ......
Page 79: ...59 PART III I O Link Unit CQM1 LK501 ...
Page 80: ......
Page 88: ......
Page 92: ......
Page 93: ...73 PART IV Analog Input Unit and Analog Power Supply Units CQM1 AD041 CQM1 IPS01 CQM1 IPS02 ...
Page 94: ......
Page 118: ......
Page 120: ......
Page 121: ...101 PART V Analog Output Unit and Analog Power Supply Units CQM1 DA021 CQM1 IPS01 CQM1 IPS02 ...
Page 122: ......
Page 126: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 156: ......
Page 172: ......
Page 186: ......
Page 187: ...167 PART VII Linear Sensor Interface Units CQM1 LSE01 CQM1 LSE02 ...
Page 188: ......
Page 192: ......
Page 204: ......
Page 218: ......
Page 238: ......
Page 242: ......
Page 246: ......
Page 248: ......
Page 250: ......